OBJECTIVE To determine how the movement of patients, equipment, materials, staff, and door openings within the operating room (OR) affect microbial loads at various locations within the OR. DESIGN Observation and sampling study. SETTING Academic health center, public hospital. METHODS We first analyzed 27 videotaped procedures to determine the areas in the OR with high and low numbers of people in transit. We then placed air samplers and settle plates in representative locations during 21 procedures in 4 different ORs during 2 different seasons of the year to measure microbial load in colony-forming units (CFU). The temperature and humidity, number of door openings, physical movement, and the number of people in the OR were measured for each procedure. Statistical analysis was conducted using hierarchical regression. RESULTS The microbial load was affected by the time of year that the samples were taken. Both microbial load measured by the air samplers and by settle plates in 1 area of the OR was correlated with the physical movement of people in the same area but not with the number of door openings and the number of people in the OR. CONCLUSIONS Movement in the OR is correlated with the microbial load. Establishing operational guidelines or developing OR layouts that focus on minimizing movement by incorporating desirable internal storage points and workstations can potentially reduce microbial load, thereby potentially reducing surgical site infection risk. Infect Control Hosp Epidemiol 2018;39:391-397.
Insights
Operating room (OR) microbial load is linked to staff movement, not door openings. Minimizing movement can reduce microbial contamination and surgical site infection risk.
Area of Science:
- Healthcare-associated infections
- Operating Room Management
- Microbiology
Background:
- Operating rooms (ORs) are critical environments for patient care.
- Understanding factors influencing microbial load in ORs is crucial for infection control.
- Patient and staff movement within ORs may impact microbial contamination.
Purpose of the Study:
- To investigate the relationship between movement of people, equipment, materials, and door openings in the OR and microbial loads.
- To identify specific OR activities that contribute to increased microbial contamination.
Main Methods:
- An observational study analyzing 27 videotaped OR procedures to identify high-traffic areas.
- Microbial load assessment using air samplers and settle plates during 21 procedures across 4 ORs.
- Measurement of environmental factors including temperature, humidity, door openings, and personnel presence.
Main Results:
- Microbial load varied seasonally.
- Physical movement of personnel within the OR correlated with microbial load.
- No significant correlation was found between microbial load and the number of door openings or the total number of people in the OR.
Conclusions:
- Personnel movement within the OR is a significant factor associated with microbial load.
- Developing OR layouts and operational guidelines to minimize movement can potentially reduce microbial contamination.
- Reducing microbial load may contribute to a lower risk of surgical site infections.
Related Concept Videos
Factors Influencing Microbial Growth: pH
Factors Influencing Microbial Growth: Temperature
Factors Influencing Microbial Growth: Osmolarity
Bioavailability: Influencing Factors
Factors Influencing Attraction I: Proximity
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...