Related Experiment Video
Updated: Feb 14, 2026

Capsular Serotyping of Streptococcus pneumoniae by Latex Agglutination
Published on: September 25, 2014
Accuracy of High-Throughput Nanofluidic PCR-Based Pneumococcal Serotyping and Quantification Assays Using Sputum
Satoshi Kakiuchi1,2, Motoi Suzuki1,2, Bhim Gopal Dhoubhadel3
1Department of Clinical Medicine, Institute of Tropical Medicine, Nagasaki University, Nagasaki, Japan.
Abstract:
The lack of reliable diagnostic tests for detecting vaccine serotype pneumococcal pneumonia (VTPP) remains a challenging issue in pneumococcal vaccine studies. This study assessed the performances of high-throughput nanofluidic PCR-based pneumococcal serotyping and quantification assay methods using sputum samples (the nanofluidic sputum quantitative PCR [Sp-qPCR] assay) to diagnose 13-valent pneumococcal conjugate VTPP compared with the performance of the serotype-specific urinary antigen detection (UAD) assay using urine samples. Adult pneumonia patients from Japan were enrolled in this study between September 2012 and August 2014. Sputum samples were subjected to the nanofluidic Sp-qPCR assay, quantitatively cultured, and serotyped by the Quellung reaction (SpQt). Urine samples were tested by the UAD method. The diagnostic performances of these tests were assessed using composite reference standards and Bayesian latent class models (BLCMs). Among 244 total patients, 27 (11.1%) tested positive with the UAD assay, while 16 (6.6%) and 34 (13.9%) tested positive with the SpQt and nanofluidic Sp-qPCR assays, respectively, with a cutoff value of ≥104 DNA copies/ml, which showed the maximum value of the Youden index. Using BLCMs, the estimated prevalence for VTPP was 12.9%, and the nanofluidic Sp-qPCR assay demonstrated the best performance (sensitivity, 90.2%; specificity, 96.9%), followed by UAD (sensitivity, 75.6%; specificity, 97.9%) and SpQt (sensitivity, 45.8%; specificity, 99.5%). However, when a higher cutoff value of ≥107 DNA copies/ml was applied, the performance of UAD became comparable to that of Sp-qPCR. The vaccine serotype-specific pneumococcal DNA load in sputum among UAD-positive patients was 3 logs higher than that among UAD-negative patients (P = 0.036). The nanofluidic Sp-qPCR assay may be accurate and useful for detecting VTPP among adults.
Related Concept Videos
Vaccinations
Improving Translational Accuracy
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
PCR
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
Uncertainty in Measurement: Accuracy and Precision

