Quantitative evaluation of the performance of different deformable image registration algorithms in helical, axial,
Imad Ali1, Nesreen Alsbou2, Justin Jaskowiak1
1Department of Radiation Oncology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA.
Abstract:
The goal of this project is to investigate quantitatively the performance of different deformable image registration algorithms (DIR) with helical (HCT), axial (ACT), and cone-beam CT (CBCT). The variations in the CT-number values and lengths of well-known targets moving with controlled motion were evaluated. Four DIR algorithms: Demons, Fast-Demons, Horn-Schunck and Lucas-Kanade were used to register intramodality CT images of a mobile phantom scanned with different imaging techniques. The phantom had three water-equivalent targets inserted in a low-density foam with different lengths (10-40 mm) and moved with adjustable motion amplitudes (0-20 mm) and frequencies (0-0.5 Hz). The variations in the CT-number level, volumes and shapes of these targets were measured from the spread-out of the CT-number distributions. In CBCT, most of the DIR algorithms were able to produce the actual lengths of the mobile targets; however, the CT-number values obtained from the DIR algorithms deviated from the actual CT-number of the targets. In HCT, the DIR algorithms were successful in deforming the images of the mobile targets to the images of the stationary targets producing the CT-number values and lengths of the targets for motion amplitudes <20 mm. Similarly in ACT, all DIR algorithms produced the actual CT-number values and lengths of the stationary targets for low-motion amplitudes <15 mm. The optical flow-based DIR algorithms such as the Horn-Schunck and Lucas-Kanade performed better than the Demons and Fast-Demons that are based on attraction forces particularly at large motion amplitudes. In conclusion, most of the DIR algorithms did not reproduce well the CT-number values and lengths of the targets in images that have artifacts induced by large motion amplitudes. The deviations in the CT-number values and variations in the volume of the mobile targets in the deformed CT images produced by the different DIR algorithms need to be considered carefully in the treatment planning for accurate dose calculation dose coverage of the tumor, and sparing of critical structures.
Related Concept Videos
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Axial and Appendicular Muscles
Axial Muscles
Axial muscles, situated along the body's midline, are intricately connected to the axial skeleton, which includes the skull, spine, ribs, and sternum. These muscles facilitate facial expressions and...