Flame figures in linear IgA bullous dermatosis: a novel histopathologic finding

E Fulton1, F Jan, M J Zimarowski

  • 1Beth Israel Deaconess Medical Center, Department of Pathology, Harvard Medical School, Boston, Massachusetts.

Dermatology Online Journal
|February 16, 2018
PubMed
Summary

This case report describes Linear IgA bullous dermatosis (LABD) with unusual eosinophilic inflammation and flame figures. These findings highlight the importance of comprehensive diagnostic methods for bullous dermatoses.

Related Concept Videos

Rules for Significant Figures01:44

Rules for Significant Figures

In any measurement, the precision of the measuring tool is an essential factor. An ordinary ruler, for example, can measure length to the closest millimeter; a caliper, on the other hand, can measure length to the nearest 0.01 mm. As a result, the caliper is a more precise measurement tool because it can measure extremely minute changes in length. The measurements will be more accurate if the measuring tool is more precise.
It should be emphasized that when we represent measured values, the...
40.3K
Uncertainty in Measurement: Significant Figures03:34

Uncertainty in Measurement: Significant Figures

All the digits in a measurement, including the uncertain last digit, are called significant figures or significant digits. Note that zero may be a measured value; for example, if a scale that shows weight to the nearest pound reads “140,” then the 1 (hundreds), 4 (tens), and 0 (ones) are all significant (measured) values.
84.2K
Significant Figures in Calculations00:58

Significant Figures in Calculations

Uncertainty in measurements can be avoided by reporting the results of a calculation with the correct number of significant figures. This can be determined by the following rules for rounding numbers:
20.2K
Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
1.6K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
990
Finding the Center of Gravity01:03

Finding the Center of Gravity

The center of gravity of a body is an imaginary point where the body's total weight is assumed to be concentrated, and the body is perfectly balanced. The center of the mass of a body is a point at which the whole of the mass of the body appears to be concentrated. If the acceleration due to gravity, g, has the same value at all points on a body, its center of gravity is identical to its center of mass. The center of gravity of homogeneous bodies such as a sphere, cube, or rectangular plate...
4.4K