Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
Single multi-echo GRE acquisition with short and long echo spacing for simultaneous quantitative mapping of fat
Junmin Liu1, Spencer D Christiansen2, Maria Drangova2
1Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine & Dentistry, University of Western Ontario, London, Ontario, Canada.
Abstract:
Multi-echo gradient echo (mGRE) sequences have been widely adapted in clinical and scientific practice for different purposes to their capability of performing Dixon MRI, generating multi-contrast images and extracting multi-parametric maps. This work aims to extend mGRE-based techniques for imaging whole head, where further technical developments are required due to the co-existence of fat and large B0 inhomogeneity in regions such as the skull base and neck. Specifically, bipolar mGRE data were acquired with a single sequence that contains both a short echo-spacing (ΔTE) echo train to capture water-fat and B0 phase shifts (for proton density fat-fraction (FF) and B0 mapping) and a longer ΔTE echo train (and long echo times) to capture subtle susceptibility variations and R2* information. The mGRE images covering the whole head (spatial resolution 1.0 × 1.0 × 2.0 mm3) were acquired in 5 min. An automated processing pipeline was implemented to use the FF and B0 maps determined from the short-TE train to compensate for the effects of fat, remove the background phase for whole-head quantitative susceptibility mapping, and reduce the difficulty of spatial phase unwrapping of the long echo-time data. Data from healthy volunteers imaged on a 3 T scanner along with phantom validation are presented. Co-registered quantitative multi-parametric maps (FF, B0 inhomogeneity, R2*, local frequency shift and quantitative susceptibility) and multi-contrast images covering the whole head were successfully generated in processing times of several minutes.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Light Acquisition
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...
Water and Mineral Acquisition

