Related Experiment Video
Updated: Feb 14, 2026

A Vibrotactile Feedback Device for Seated Balance Assessment and Training
Published on: January 20, 2019
Balance assessment during squatting exercise: A comparison between laboratory grade force plate and a commercial,
Alessandro Mengarelli1, Federica Verdini1, Stefano Cardarelli1
1Department of Information Engineering, Università Politecnica delle Marche, 60131 Ancona, Italy.
Abstract:
Testing balance through squatting exercise is a central part of many rehabilitation programs and sports and plays also an important role in clinical evaluation of residual motor ability. The assessment of center of pressure (CoP) displacement and its parametrization is commonly used to describe and analyze squat movement and the laboratory-grade force plates (FP) are the gold standard for measuring balance performances from a dynamic view-point. However, the Nintendo Wii Balance Board (NWBB) has been recently proposed as an inexpensive and easily available device for measuring ground reaction force and CoP displacement in standing balance tasks. Thus, this study aimed to compare the NWBB-CoP data with those obtained from a laboratory FP during a dynamic motor task, such as the squat task. CoP data of forty-eight subjects were acquired simultaneously from a NWBB and a FP and the analyses were performed over the descending squatting phase. Outcomes showed a very high correlation (r) and limited root-mean-square differences between CoP trajectories in anterior-posterior (r > 0.99, 1.63 ± 1.27 mm) and medial-lateral (r > 0.98, 1.01 ± 0.75 mm) direction. Spatial parameters computed from CoP displacement and ground reaction force peak presented fixed biases between NWBB and FP. Errors showed a high consistency (standard deviation < 2.4% of the FP outcomes) and a random spread distribution around the mean difference. Mean velocity is the only parameter which exhibited a tendency towards proportional values. Findings of this study suggested the NWBB as a valid device for the assessment and parametrization of CoP displacement during squatting movement.
More Related Videos
07:52Assessment of Murine Exercise Endurance Without the Use of a Shock Grid: An Alternative to Forced Exercise
Published on: August 14, 2014
07:39Co-culture of Glutamatergic Neurons and Pediatric High-Grade Glioma Cells Into Microfluidic Devices to Assess Electrical Interactions
Published on: November 17, 2021
Related Concept Videos
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Balancing Redox Equations
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...
Intermolecular Forces
Molecular Comparison of Gases, Liquids, and Solids