Related Experiment Video
Updated: Feb 14, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Are ICD recipients able to foresee if they want to withdraw therapy or deactivate defibrillator shocks?
Ingela Thylén1,2, Debra K Moser3, Misook L Chung3
1Division of Nursing Sciences, Department of Medicine and Health Sciences, Faculty of Health Sciences, Linköping University, Department of Cardiology, County Council of Östergötland, Linköping, Sweden.
Background:
Expert consensus statements on management of implantable cardioverter defibrillators (ICDs) emphasize the importance of having discussions about deactivation before and after implantation. These statements were developed with limited patient input. The purpose of this study was to identify the factors associated with patients' experiences of end-of-life discussions, attitudes towards such discussions, and attitudes towards withdrawal of therapy (i.e., generator replacement and deactivation) at end-of-life, in a large national cohort of ICD-recipients.
Methods:
We enrolled 3067 ICD-patients, administrating the End-of-Life-ICD-Questionnaire.
Results:
Most (86%) had not discussed ICD-deactivation with their physician. Most (69%) thought discussions were best at end-of-life, but 40% stated that they never wanted the physician to initiate a discussion. Those unwilling to discuss deactivation were younger, had experienced battery replacement, had a longer time since implantation, and had better quality-of-life. Those with psychological morbidity were more likely to desire a discussion about deactivation. Many patients (39%) were unable to foresee what to decide about deactivation in an anticipated terminal condition. Women, those without depression, and those with worse ICD-related experiences were more indecisive about withdrawal of therapy. Irrespective of shock experiences, those who could take a stand regarding deactivation chose to keep shock therapies active in many cases (39%).
Conclusions:
Despite consensus statements recommending discussions about ICD-deactivation at the end-of-life, such discussion usually do not occur. There is substantial ambivalence and indecisiveness on the part of most ICD-patients in this nationwide survey about having these discussions and about expressing desires about deactivation in an anticipated end-of-life situation.
Related Concept Videos
Deactivation Processes: Jablonski Diagram
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
ortho–para-Directing Deactivators: Halogens
Gene Therapy
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...