Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Variance01:15

Variance

12.6K
The deviations show how spread out the data are about the mean. A positive deviation occurs when the data value exceeds the mean, whereas a negative deviation occurs when the data value is less than the mean. If the deviations are added, the sum is always zero. So one cannot simply add the deviations to get the data spread. By squaring the deviations, the numbers are made positive; thus, their sum will also be positive.
The standard deviation measures the spread in the same units as the data....
12.6K
Reliability and Validity01:29

Reliability and Validity

14.1K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
14.1K
Friedman Two-way Analysis of Variance by Ranks01:21

Friedman Two-way Analysis of Variance by Ranks

512
Friedman's Two-Way Analysis of Variance by Ranks is a nonparametric test designed to identify differences across multiple test attempts when traditional assumptions of normality and equal variances do not apply. Unlike conventional ANOVA, which requires normally distributed data with equal variances, Friedman's test is ideal for ordinal or non-normally distributed data, making it particularly useful for analyzing dependent samples, such as matched subjects over time or repeated measures...
512
Data Validation01:15

Data Validation

2.4K
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
2.4K
Data Validation01:03

Data Validation

7.0K
Data validation is an essential part of a comprehensive assessment. Validation is confirming or verifying and opening the door to gathering more assessment data as it clarifies vague or unclear data. The process of checking and verifying the collected information is called data validation. The primary purpose of data validation is to ensure data is as free from error, bias, and misinterpretation as possible.
Nursing assessment guides are generally based on holistic models rather than medical...
7.0K
Integration of Synaptic Events01:28

Integration of Synaptic Events

4.3K
Synaptic integration mainly includes the summation of graded potentials. Graded potentials, regardless of their type, cause subtle alterations in membrane voltage, resulting in either depolarization or hyperpolarization. These incremental changes, when combined or summed, can propel the neuron toward its threshold. Consider, for example, a membrane experiencing a +15 mV shift, causing it to depolarize from -70 mV to -55 mV. In this scenario, graded potentials govern the membrane's ability to...
4.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A protocol to simultaneously examine cardiorespiratory, cerebrovascular and neurophysiological responses inside a hypobaric chamber.

PloS one·2024
Same author

Combining clinostating and proton irradiation for modeling the space environment: a case study with a Chernobyl accession of <i>Arabidopsis thaliana</i>.

International journal of radiation biology·2024
Same author

Classifying Routine Clinical Electroencephalograms With Multivariate Iterative Filtering and Convolutional Neural Networks.

IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society·2024
Same author

Biological Efficacy of Ionizing Radiation Sources on 3D Organotypic Tissue Slices Assessed by Fluorescence Microscopy.

Current radiopharmaceuticals·2024
Same author

Comparative Analysis of the Effect of Gamma-, Electron, and Proton Irradiation on Transcriptomic Profile of <i>Hordeum vulgare</i> L. Seedlings: In Search for Molecular Contributors to Abiotic Stress Resilience.

Plants (Basel, Switzerland)·2024
Same author

Detection of acute and early-delayed radiation-induced changes in the white matter of the rat brain based on numerical processing of optical coherence tomography data.

Journal of biophotonics·2024
Same journal

Diffusion-Informed Joint Segmentation Enhances Detection of Thalamic Atrophy in Parkinson's Disease.

Brain topography·2026
Same journal

Local Field Potential Recordings Using Deep Brain Stimulation: A Practical Workflow and Open-Source Signal Processing Pipeline.

Brain topography·2026
Same journal

Electrocortical Indices of Default Mode Network-Related Activity in ADHD and Modulation Through Mindfulness-Based Cognitive Therapy.

Brain topography·2026
Same journal

Electroencephalogram for the Diagnosis of Depression: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy.

Brain topography·2026
Same journal

Mapping Whole-Brain Nonlinear Structure-Function Dynamics in Aging via Neural Granger Causality.

Brain topography·2026
Same journal

Association Between Spatiotemporal Properties of Global Brain Activity and Childhood Emotional and Behavioral Problems: Evidence from Microstate C.

Brain topography·2026
See all related articles

Related Experiment Video

Updated: Feb 14, 2026

How to Obtain Reliable Visual Event-related Potentials in Newborns
07:39

How to Obtain Reliable Visual Event-related Potentials in Newborns

Published on: October 24, 2019

6.8K

Localizing Event-Related Potentials Using Multi-source Minimum Variance Beamformers: A Validation Study.

Anthony T Herdman1,2, Alexander Moiseev3, Urs Ribary3,4

  • 1Faculty of Medicine, School of Audiology and Speech Sciences, University of British Columbia, 2177 Wesbrook Mall, Vancouver, V6T 1Z3, Canada. aherdman@audiospeech.ubc.ca.

Brain Topography
|February 17, 2018
PubMed
Summary
This summary is machine-generated.

Multi-source beamformers significantly improve electroencephalography (EEG) source localization compared to single-source methods. A new multi-step iterative approach (MIA) offers superior performance in pinpointing neural activity and reconstructing waveforms.

More Related Videos

High Density Event-related Potential Data Acquisition in Cognitive Neuroscience
08:33

High Density Event-related Potential Data Acquisition in Cognitive Neuroscience

Published on: April 16, 2010

13.0K
Infant Auditory Processing and Event-related Brain Oscillations
06:34

Infant Auditory Processing and Event-related Brain Oscillations

Published on: July 1, 2015

17.0K

Related Experiment Videos

Last Updated: Feb 14, 2026

How to Obtain Reliable Visual Event-related Potentials in Newborns
07:39

How to Obtain Reliable Visual Event-related Potentials in Newborns

Published on: October 24, 2019

6.8K
High Density Event-related Potential Data Acquisition in Cognitive Neuroscience
08:33

High Density Event-related Potential Data Acquisition in Cognitive Neuroscience

Published on: April 16, 2010

13.0K
Infant Auditory Processing and Event-related Brain Oscillations
06:34

Infant Auditory Processing and Event-related Brain Oscillations

Published on: July 1, 2015

17.0K

Area of Science:

  • Neuroimaging
  • Biophysics
  • Signal Processing

Background:

  • Adaptive and non-adaptive beamformers are key tools for localizing neural sources using electroencephalography (EEG) and magnetoencephalography (MEG) data.
  • Accurate source localization is crucial for understanding brain function and dysfunction.

Purpose of the Study:

  • To evaluate the performance of single-source and multi-source beamformer approaches for EEG source localization and reconstruction.
  • To compare a novel multi-step iterative approach (MIA) against existing single-step iterative (SIA) and single-step peak (SPA) methods.

Main Methods:

  • Simulated EEG data with varying signal-to-noise ratios, inter-source correlations, number of sources, and locations were used.
  • Performance was assessed by comparing localization accuracy, precision, and source waveform reconstruction across MIA, SIA, and SPA.

Main Results:

  • Localization performance consistently ranked MIA > SIA > SPA across all tested parameters.
  • Multi-source methods (SIA and MIA) outperformed the single-source approach (SPA), especially with four or more sources.
  • MIA demonstrated superior localization and waveform reconstruction, particularly under challenging signal conditions.

Conclusions:

  • Multi-source beamformers represent a significant advancement over single-source methods for EEG source localization.
  • The proposed MIA method provides enhanced localization performance, precision, and waveform reconstruction accuracy.
  • MIA is recommended for improved analysis of event-related potentials in EEG data.