Related Experiment Video
Updated: Feb 14, 2026

Author Spotlight: Advancing 3D Coculture Systems with PVA-PCL Nanofibrous Membranes
Published on: December 27, 2024
Polyamide 6-LiCl nanofibrous membrane as low-temperature regenerative desiccant with improved stability
Fengjing Jiang1, Li Dai2, Ye Yao2
1Institute of Fuel Cell, School of Mechanical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Rd., Shanghai, 200240, People's Republic of China.
None:
Polyamide 6-LiCl (PA 6-LiCl) electrospun nanofibrous membranes (NFMs) have been successfully prepared as novel solid desiccant materials. The PA 6 NFM with 20% LiCl mass ratio had a sorption capacity of 1.8 g g-1 at 25 °C and 95% relative humidity, which was 4 times more than that of silica gels. The desorption isobars of the NFMs indicated that over 85% of sorbed water in the NFMs can be desorbed at about 50 °C, and the low regeneration temperature made it promising as an energy-saving desiccant material. The experimental results manifested that the sorption/desorption kinetics of the NFMs better fit the pseudo-second order model. According to scanning electron microscope images and the cycle experiment, the NFMs were also found to possess notably improved stability against moisture and could be recycled with little degradation of performance, which confirmed the practicability of the new desiccant membranes.
More Related Videos
10:24Regenerative Therapy by Suprachoroidal Cell Autograft in Dry Age-related Macular Degeneration: Preliminary In Vivo Report
Published on: February 12, 2018
03:01Author Spotlight: A Reproductive Hysteroscopy Approach for Complete Endometrial Polyp Removal and Enhanced Endometrial Receptivity
Published on: August 2, 2024
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Nuclear Stability
To hold positively charged protons together...
RNA Stability
Stability
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
Stability of structures
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...