Related Experiment Video
Updated: Feb 14, 2026

Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Transnasal humidified rapid insufflation ventilatory exchange for oxygenation of children during apnoea: a
T Riva1, T H Pedersen1, S Seiler1
1Department of Anaesthesiology & Pain Therapy, Bern University Hospital, Inselspital, Freiburgstrasse 8, 3010 Bern, Switzerland.
Background:
Transnasal humidified rapid insufflation ventilatory exchange (THRIVE) comprises the administration of heated, humidified, and blended air/oxygen mixtures via nasal cannula at rates of ≥2 litres kg-1 min-1. The aim of this randomized controlled study was to evaluate the length of the safe apnoea time using THRIVE with two different oxygen concentrations (100% vs 30% oxygen) compared with standard low-flow 100% oxygen administration.
Methods:
Sixty patients, aged 1-6 yr, weighing 10-20 kg, undergoing general anaesthesia for elective surgery, were randomly allocated to receive one of the following oxygen administration methods during apnoea: 1) low-flow 100% oxygen at 0.2 litres kg-1 min-1; 2) THRIVE 100% oxygen at 2 litres kg-1 min-1; and 3) THRIVE 30% oxygen at 2 litres kg-1 min-1. Primary outcome was time to desaturation to 95%. Termination criteria included SpO2 decreased to 95%, transcutaneous CO2 increased to 65 mmHg, or apnoea time of 10 min.
Results:
The median (interquartile range) [range] apnoea time was 6.9 (5.7-7.8) [2.8-10.0] min for low-flow 100% oxygen, 7.6 (6.2-9.1) [5.2-10.0] min for THRIVE 100% oxygen, and 3.0 (2.4-3.7) [0.2-5.3] min for THRIVE 30% oxygen. No significant difference was detected between apnoea times with low-flow and THRIVE 100% oxygen administration (P=0.15). THRIVE with 30% oxygen demonstrated significantly shorter apnoea times (P<0.001) than both 100% oxygen modalities. The overall rate of transcutaneous CO2 increase was 0.57 (0.49-0.63) [0.29-8.92] kPa min-1 without differences between the 3 groups (P=0.25).
Conclusions:
High-flow 100% oxygen (2 litres kg-1 min-1) administered via nasal cannulas did not extend the safe apnoea time for children weighing 10-20 kg compared with low-flow nasal cannula oxygen (0.2 litres kg-1 min-1). No ventilatory effect was observed with THRIVE at 2.0 litres kg-1 min-1.
Clinical Trial Registration:
NCT02979067.
More Related Videos
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Gas Exchange and Transport
Social Exchange Theory
Social Exchange Theory
Trial and Error and Algorithm
Clinical Trials: Overview