Related Experiment Video
Updated: Feb 14, 2026

Isolated Hepatic Perfusion as a Treatment for Liver Metastases of Uveal Melanoma
Published on: January 25, 2015
Retina dose as a predictor for visual acuity loss in 106Ru eye plaque brachytherapy of uveal melanomas
Gerd Heilemann1, Lukas Fetty1, Matthias Blaickner2
1Division Medical Radiation Physics, Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/AKH Vienna, Austria.
Background And Purpose:
To evaluate the retina dose as a risk factor associated with loss of visual acuity (VA) in 106Ru plaque brachytherapy.
Material/Methods:
45 patients receiving 106Ru plaques brachytherapy (median follow-up 29.5 months) were included in this study. An in-house developed treatment planning system with Monte Carlo based dose calculation was used to perform treatment planning and dose calculation. Risk factors associated with loss of VA were evaluated using the Cox proportional hazards models, Kaplan-Meier estimates and Pearson correlation coefficients.
Results:
A significant correlation was found between VA loss and mean (r = 0.49, p = 0.001) and near maximum (r = 0.47, p = 0.001) retina dose D2% and tumor basal diameter (r = 0.50, p < 0.001). The Kaplan-Meier and Cox proportional hazards model yielded a significantly higher risk for VA loss (>0.3Snellen) for patients receiving a maximum dose of >500 Gy (p = 0.002). A Cox multivariate analysis including the macula dose (p = 0.237) and basal diameter (p = 0.791) showed that a high maximum retinal dose is the best risk factor (p = 0.013) for VA loss.
Conclusion:
The study showed that retina dose (D2% and Dmean) is a suitable predictor for VA loss.
More Related Videos
05:10Author Spotlight: An Automated Method for Assessing Visual Acuity in Infants and Toddlers Using an Eye-Tracking System
Published on: March 17, 2023
06:25Author Spotlight: Assessment of Visual Acuity in Central Vision Loss Through Motion-Based Peripheral Vision Testing
Published on: February 23, 2024
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
The Retina
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...