New Methods to Assess Forearm Torque and Lifting Strength: Reliability and Validity.
Peter Axelsson1, Johan Kärrholm2
1Department of Hand Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.
New dynamometers offer reliable and valid measurements for forearm torque and lifting strength. These simple clinical methods can enhance the evaluation and treatment of wrist and forearm conditions.
Area of Science:
- Biomechanics
- Clinical Measurement
- Rehabilitation Science
Background:
- Objective measurement of forearm torque and lifting strength is crucial for assessing wrist and forearm disorders.
- Existing methods may lack repeatability or validity in clinical settings.
Purpose of the Study:
- To determine the repeatability and validity of new methods for objectively measuring forearm torque and lifting strength in a clinical setting.
- To compare the performance of new dynamometers (Baseline and Kern) against a reference standard (Work Simulator II, Baltimore Therapeutic Equipment - BTE II).
Main Methods:
- Twenty-eight healthy volunteers were tested for lifting strength and forearm torque using Kern and Baseline dynamometers.
- Two raters assessed participants on three occasions, with one rater also testing in a seated position and using the BTE II.
- Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to assess intra- and interrater reliability and validity.
Main Results:
- Excellent intra- and interrater reliability (ICCs 0.88–0.96) was found for forearm torque measurements with both Baseline and BTE II.
- Comparisons between Baseline and BTE II showed substantial agreement (ICCs 0.74–0.88).
- Lifting strength measurements demonstrated high reliability (ICCs 0.84–0.96) and strong agreement between Kern and BTE II (ICCs 0.91–0.95).
Conclusions:
- The Baseline and Kern dynamometers exhibit excellent intra- and interrater repeatability for forearm torque and lifting strength.
- The new methods are valid when compared to the BTE II, with the exception of forearm pronation torque (ICC 0.74).
- Measurements in standing or seated positions showed minimal difference, indicating the methods' suitability for future clinical studies.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
07:30Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
Related Concept Videos
Net Torque Calculations
Torque
Torque can be considered as the rotational counterpart to force. Since forces change the translational...