A preliminary exploration of plain-film radiography in scapular dyskinesis evaluation
Kang Chen1, Simin Deng1, Yanhong Ma1
1Department of Rehabiliation Medicine, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Background:
Evaluation of scapular dyskinesis is of clinical interest because it is believed to be associated with pathologies of the shoulder. This study investigated the feasibility of plain-film radiography in evaluating scapular dyskinesis.
Methods:
Subjects with unilateral disorders of the shoulder (n = 186) who underwent plain-film radiography of bilateral scapulae were divided into 4 categories of scapular dyskinesis patterns according to the Kibler classification and analyzed. Coracoid upward shift distance (CUSD), length of the scapular spine line (LSS), and scapular upward rotation angle (SURA) were measured on the radiographs. Intrarater and inter-rater reliability were tested, and the characteristics of these parameters in each type were analyzed. The differences (d) between bilateral scapulae (d-CUSD, d-LSS, and d-SURA) among the 4 categories were compared.
Results:
Intrarater and inter-rater reliability were excellent for all parameters. Significant differences between the scapulae were observed in CUSD in type I and in LSS in type II categories. No significant difference in any of the parameters was found in type III. Compared with the other categories, d-CUSD in type I and d-LSS in type II were significantly larger. The cutoff values of d-CUSD and d-LSS were 1.1 mm and 1.2 mm, respectively. No significant difference in d-SURA was found among the 4 categories.
Conclusions:
The measurement of CUSD, LSS, and SURA on plain-film radiography had excellent reliability. d-CUSD and d-LSS were characteristic parameters of type I and type II, respectively; however, type III had no distinguishing characteristics among the parameters.
More Related Videos
10:07Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Nursing Evaluation
Self-Evaluation Maintenance Model
Dysrhythmias V: Evaluating Dysrhythmias
Social Foundations of Self III: Self-Evaluation
Evaluating Limits by Direct Substitution