Characterization of cellular and matrix alterations in the early pathogenesis of osteochondritis dissecans in pigs

Andreas Finnøy1, Kristin Olstad2, Magnus B Lilledahl1

  • 1Department of Physics, Norwegian University of Science and Technology (NTNU), Høgskoleringen 5, Trondheim, 7491, Norway.

Related Concept Videos

Harmonic Mean01:09

Harmonic Mean

The arithmetic mean is usually skewed towards the larger values in the data set. Therefore, to avoid this inherent bias towards smaller values, the harmonic mean is used.
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
3.8K
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
21.2K
The Extracellular Matrix01:42

The Extracellular Matrix

Overview
89.5K
Alterations in Respiration II01:30

Alterations in Respiration II

There are numerous types of normal and abnormal respiration. Based on ventilatory movements, breathing patterns are classified as regular, deep, or shallow. Examples include Biot's breathing, Cheyne-Stokes respiration, Kussmaul's breathing, hyperventilation, and hypoventilation. Each pattern is clinically significant and aids in evaluating patients.
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
1.9K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.6K
Simple Harmonic Motion01:21

Simple Harmonic Motion

Simple harmonic motion is the name given to oscillatory motion for a system where the net force can be described by Hooke's law. If the net force can be described by Hooke's law and there is no damping (by friction or other non-conservative forces), then a simple harmonic oscillator will oscillate with equal displacement on either side of the equilibrium position. To derive an equation for period and frequency, the equation of motion is used. The period of a simple harmonic oscillator is given...
15.4K