False-Positive and False-Negative Results of Motor Evoked Potential Monitoring During Surgery for Intramedullary
Ryu Kurokawa1, Phyo Kim1, Kazushige Itoki1
1Department of Neurologic Surgery, Dok-kyo University Hospital, Mibu, Tochigi, Japan.
Background:
Motor evoked potential (MEP) recording is used as a method to monitor integrity of the motor system during surgery for intramedullary tumors (IMTs). Reliable sensitivity of the monitoring in predicting functional deterioration has been reported. However, we observed false positives and false negatives in our experience of 250 surgeries of IMTs.
Objective:
To delineate specificity and sensitivity of MEP monitoring and to elucidate its limitations and usefulness.
Methods:
From 2008 to 2011, 58 patients underwent 62 surgeries for IMTs. MEP monitoring was performed in 59 operations using transcranial electrical stimulation. Correlation with changes in muscle strength and locomotion was analyzed. A group undergoing clipping for unruptured aneurysms was compared for elicitation of MEP.
Results:
Of 212 muscles monitored in the 59 operations, MEP was recorded in 150 (71%). Positive MEP warnings, defined as amplitude decrease below 20% of the initial level, occurred in 37 muscles, but 22 of these (59%) did not have postoperative weakness (false positive). Positive predictive value was limited to 0.41. Of 113 muscles with no MEP warnings, 8 muscles developed postoperative weakness (false negative, 7%). Negative predictive value was 0.93. MEP responses were not elicited in 58 muscles (27%). By contrast, during clipping for unruptured aneurysms, MEP was recorded in 216 of 222 muscles (96%).
Conclusion:
MEP monitoring has a limitation in predicting postoperative weakness in surgery for IMTs. False-positive and false-negative indices were abundant, with sensitivity and specificity of 0.65 and 0.83 in predicting postoperative weakness.
More Related Videos
Related Concept Videos
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information...
Positive, Negative, and Zero Work
Spinal Cord
The Spinal Cord
Positive and Negative Feedback Loops
Spinal Cord: Information Processing
Sensory Information Processing
Sensory information processing begins at the sensory receptors located in the skin and other tissues, which detect somatic sensory stimuli such as touch, temperature, or pain. These receptors function as catalysts, initiating...