Related Experiment Video
Updated: Feb 14, 2026

Anterior Cervical Discectomy and Fusion in the Ovine Model
Published on: October 5, 2009
Use of a Pediatric Craniotome Drill for Cervical and Thoracic Spine Decompression: Safety and Efficacy
Christopher Elia1, Omid R Hariri2, Jason Duong1
1Division of Neurosurgery, Riverside University Health System Medical Center, Moreno Valley, California, USA; Division of Neurosurgery, Arrowhead Regional Medical Center, Colton, California, USA.
Background:
Laminectomy, using a high-speed drill with an unprotected cutting drill bit, can be rapid and effective, but it has been associated with known complications. Another technique uses a pediatric craniotome drill with the footplate attachment. At present, there are no studies comparing clinical outcomes between these 2 stated decompressive techniques.
Methods:
A retrospective review was conducted at a single institution. Two cohorts of patients were considered based on the technical method of laminectomy for decompression. One group had decompression with utilization of a high-speed drill, whereas the other group had decompression with a pediatric craniotome drill with a footplate attachment. The outcomes from each group were compared based on the length of operation, estimated blood loss, and associated complications.
Results:
A total of 91 patients were included in the final analysis. Forty-five of the patients underwent laminectomy using a footplate and 46, using a high-speed drill. The footplate group was associated with significantly shorter operative time (159 vs. 205 minutes; P = 0.008). In addition, the footplate technique demonstrated less estimated blood loss (254 vs. 349 mL), and less incidence of durotomies (2.2% vs. 10.9%); however, neither of these 2 outcomes achieved statistical significance.
Conclusions:
Despite being an older technique, there was a shorter operative time in the footplate group without increased blood loss or incidence of durotomy. Although comparable results are operator dependent, this technique is a safe alternative for performing cervical and thoracic laminectomies.
Related Concept Videos
Survey Safety
Thoracic Aorta
Self-Efficacy
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...