Far-UVC light prevents MRSA infection of superficial wounds in vivo
Brian Ponnaiya1, Manuela Buonanno1, David Welch1
1Center for Radiological Research, Department of Radiation Oncology, Columbia University Medical Center, New York, New York, United States of America.
Background:
Prevention of superficial surgical wound infections from drug-resistant bacteria such as methicillin resistant Staphylococcus aureus (MRSA) currently present major health care challenges. The majority of surgical site infections (SSI) are believed to be caused by airborne transmission of bacteria alighting onto the wound during surgical procedures. We have previously shown that far-ultraviolet C light in the wavelength range of 207-222 nm is significantly harmful to bacteria, but without damaging mammalian cells and tissues. It is important that the lamp be fitted with a filter to remove light emitted at wavelengths longer than 230 nm which are harmful.
Aims:
Using a hairless mouse model of infection of superficial wounds, here we tested the hypothesis that 222-nm light kills MRSA alighting onto a superficial skin incisions as efficiently as typical germicidal light (254 nm), but without inducing skin damage.
Methods:
To simulate the scenario wherein incisions are infected during surgical procedures as pathogens in the room alight on a wound, MRSA was spread on a defined area of the mouse dorsal skin; the infected skin was then exposed to UVC light (222 nm or 254 nm) followed by a superficial incision within the defined area, which was immediately sutured. Two and seven days post procedure, bactericidal efficacy was measured as MRSA colony formation unit (CFU) per gram of harvested skin whereas fixed samples were used to assess skin damage measured in terms of epidermal thickness and DNA photodamage.
Results:
In the circumstance of superficial incisions infected with bacteria alighting onto the wound, 222-nm light showed the same bactericidal properties of 254-nm light but without the associated skin damage.
Conclusions:
Being safe for patient and hospital staff, our results suggested that far-UVC light (222 nm) might be a convenient approach to prevent transmission of drug-resistant infectious agents in the clinical setting.
Insights
Far-ultraviolet C (222 nm) light effectively kills bacteria on wounds, similar to traditional germicidal light, but without causing skin damage. This offers a safe new method for preventing surgical site infections from drug-resistant bacteria.
Area of Science:
- Microbiology
- Photobiology
- Dermatology
Background:
- Surgical site infections (SSIs) caused by drug-resistant bacteria like methicillin-resistant Staphylococcus aureus (MRSA) pose significant healthcare challenges.
- Airborne transmission of bacteria during surgery is a primary cause of SSIs.
- Far-ultraviolet C (far-UVC) light (207–222 nm) effectively kills bacteria without harming human cells, provided harmful longer wavelengths are filtered out.
Purpose of the Study:
- To evaluate the efficacy of 222 nm far-UVC light in killing MRSA on superficial wounds compared to 254 nm germicidal light.
- To assess the potential for skin damage induced by 222 nm far-UVC light in a murine model.
Main Methods:
- A hairless mouse model was used to simulate superficial wound infections with MRSA.
- Bacterial contamination was followed by exposure to either 222 nm or 254 nm UVC light before incision and suturing.
- Bactericidal efficacy (MRSA CFU/gram) and skin damage (epidermal thickness, DNA photodamage) were assessed post-procedure.
Main Results:
- 222 nm far-UVC light demonstrated equivalent bactericidal efficacy against MRSA as 254 nm germicidal light.
- Crucially, 222 nm far-UVC light did not induce significant skin damage, unlike 254 nm light.
Conclusions:
- 222 nm far-UVC light is as effective as traditional germicidal light in eliminating bacteria on superficial wounds.
- Its safety profile makes far-UVC light a promising tool for preventing the transmission of infectious agents in clinical settings.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Cancer Prevention
Some...
Prevention of Further Absorption of Poison
Preventive Healthcare Services
Light Acquisition
Light as Energy
Photons
A photon is a discrete electromagnetic particle or bundle of energy. Photons are characterized by their frequency, wavelength, and amplitude, similar to the properties of a wave. Waves with higher frequencies transmit more energy and have shorter wavelengths than longer wavelengths that transmit...


