Background:
Using a two-dimensional ultrasound-guided approach does not guarantee success during the first attempt at internal jugular vein cannulation. Our randomized, parallel simulation study examined whether a new disposable device could improve the success rate of the first attempt at ultrasound-guided internal jugular vein cannulation of a simulated internal jugular vein.
Methods:
Eighty-eight participants were randomized to perform needle insertion for internal jugular vein cannulation of a phantom using the ultrasound-guided approach with (case group) or without (control group) this new device. The primary outcome was the success rate of the first attempt. The secondary outcome was the frequency of mechanical complications such as arterial puncture and posterior wall puncture, procedure time, and level of difficulty.
Results:
Among 44 participants using the device, 33 (75.0%) achieved successful cannulation on the first attempt. However, only 12 (27.3%) of the 44 participants not using the device recorded success during the first attempt (risk difference, 0.477; 95% confidence interval [CI] 0.294-0.661; P<0.001). The number of attempts was significantly lower (risk difference, -3.955; 95% CI, -5.014 to -3.712; P<0.001) when participants performed cannulation with the device (1.63±1.71) than without the device (5.59±5.78). Our study also showed that participants were comfortable when performing the ultrasound-guided approach with the new device (risk difference, -1.955; 95% CI, -2.016 to -1.493; P<0.0001).
Conclusions:
The new disposable device was effective for successful first attempts at needle insertion during ultrasound-guided internal jugular vein cannulation. Future clinical trials are needed to assess the effectiveness of this device.
More Related Videos
08:27Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.
Published on: January 27, 2015
15:21Training a Sophisticated Microsurgical Technique: Interposition of External Jugular Vein Graft in the Common Carotid Artery in Rats
Published on: November 11, 2012
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...