Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Improving Translational Accuracy02:07

Improving Translational Accuracy

15.0K
Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.0K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.7K
3.7K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

105.2K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
105.2K
pH Scale02:41

pH Scale

80.4K
Hydronium and hydroxide ions are present both in pure water and in all aqueous solutions, and their concentrations are inversely proportional as determined by the ion product of water (Kw). The concentrations of these ions in a solution are often critical determinants of the solution’s properties and the chemical behaviors of its other solutes. Two different solutions can differ in their hydronium or hydroxide ion concentrations by a million, billion, or even trillion times. A common means of...
80.4K
Accuracy and Precision01:52

Accuracy and Precision

15.7K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
15.7K
Accuracy, limits, and approximation01:28

Accuracy, limits, and approximation

1.3K
Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
1.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Biological kinematics: a detailed review of the velocity-curvature power law calculation.

Experimental brain research·2025
Same author

Cortical depth profiles in primary visual cortex for illusory and imaginary experiences.

Nature communications·2024
Same author

Erratum: Touching with the eyes: Oculomotor self-touch induces illusory body ownership.

iScience·2023
Same author

Touching with the eyes: Oculomotor self-touch induces illusory body ownership.

iScience·2023
Same author

A methodological framework to assess the accuracy of virtual reality hand-tracking systems: A case study with the Meta Quest 2.

Behavior research methods·2023
Same author

Skin properties and afferent density in the deterioration of tactile spatial acuity with age.

The Journal of physiology·2022

Related Experiment Video

Updated: Feb 14, 2026

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder
06:46

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder

Published on: June 7, 2024

1.4K

Musical Scales in Tone Sequences Improve Temporal Accuracy.

Min S Li1, Massimiliano Di Luca1

  • 1Centre for Computational Neuroscience and Cognitive Robotics, School of Psychology, University of Birmingham, Birmingham, United Kingdom.

Frontiers in Psychology
|February 23, 2018
PubMed
Summary

Predicting stimulus timing is enhanced by non-temporal patterns. Musical scales improve the detection of timing deviations in auditory sequences, suggesting predictability influences time perception.

Keywords:
expectationisochronymusical scaleperceived timingtemporal sensitivitytone frequency

More Related Videos

Driving Under the Influence: How Music Listening Affects Driving Behaviors
07:25

Driving Under the Influence: How Music Listening Affects Driving Behaviors

Published on: March 27, 2019

13.2K
Method to Measure Tone of Axial and Proximal Muscle
10:41

Method to Measure Tone of Axial and Proximal Muscle

Published on: December 14, 2011

18.0K

Related Experiment Videos

Last Updated: Feb 14, 2026

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder
06:46

Author Spotlight: Enhanced Urodynamic Method for Precise Urine Measurement in Awake Mice with Neurogenic Bladder

Published on: June 7, 2024

1.4K
Driving Under the Influence: How Music Listening Affects Driving Behaviors
07:25

Driving Under the Influence: How Music Listening Affects Driving Behaviors

Published on: March 27, 2019

13.2K
Method to Measure Tone of Axial and Proximal Muscle
10:41

Method to Measure Tone of Axial and Proximal Muscle

Published on: December 14, 2011

18.0K

Area of Science:

  • Cognitive psychology
  • Auditory perception
  • Temporal processing

Background:

  • Perceived timing relies on stimulus properties like rhythm.
  • Influence of non-temporal properties on predicting stimulus timing is underexplored.
  • Understanding how non-temporal patterns affect temporal deviation detection is crucial.

Purpose of the Study:

  • To investigate how non-temporal patterns in auditory sequences influence the detection of temporal deviations.
  • To determine if musical scales improve or bias the perception of timing errors.
  • To assess the impact of sequence length and final tone predictability on temporal judgment sensitivity.

Main Methods:

  • Participants judged temporal deviations in sequences of 3-6 auditory tones.
  • Sequences featured either musical scales or random tones.
  • Two experiments varied sequence length and final tone predictability.
  • Performance was measured by the discriminability of anisochrony (timing deviations).

Main Results:

  • Higher discriminability of temporal deviations was observed with musical scales compared to random tones.
  • Longer sequences also led to better detection of timing errors.
  • These improvements were consistent regardless of whether the final tone was predictable.

Conclusions:

  • Predictability of non-temporal properties, like musical scales, enhances sensitivity to temporal deviations.
  • Musical patterns improve time judgments, suggesting a link between pattern recognition and temporal perception.
  • Non-temporal sequence characteristics play a significant role in auditory timing perception.