Related Experiment Video
Updated: Feb 14, 2026

Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Large Calibre Self-Expanding Stents for Pulmonary Stenosis After the Arterial Switch, a Low-Risk Solution to a
Gareth J Morgan1,2,3, Kuberan Pushparajah4,5, Srinivas Narayan4,5
1The Heart Institute, Childrens' Hospital of Colorado, University of Colorado, Anschutz Medical Campus, East 16th Avenue, Denver, CO, 80045, USA. drgarethjmorgan@gmail.com.
Abstract:
Branch pulmonary artery stenosis is one of the most common complications late after the arterial switch operation. The pathophysiology of stenosis in these circumstances is very different to that encountered in with normally related great vessels. The LeCompte manoeuvre leaves the pulmonary arteries straddled and stretched over the aortic root which contributing significantly to the degree of stenosis encountered. Unilateral branch pulmonary artery stenosis rarely leads to significant symptoms in young patients with biventricular repairs; however, significant discrepancies in the split flows between right and left lung may place the patient in an unfavourable physiological position as they move in to middle age. Balloon expandable stent implantation distorts the anatomical arrangement of the LeCompte and is associated with negative interactions with the often dilated aortic root. We present three cases of the use of flexible self-expanding stents to improve the physiological flow distributions to each lung whilst hopefully decreasing the risk of erosion and perforation or fistula formation related to the pulmonary artery. All three patients had uncomplicated procedures with significant improvements in vessel diameter and flow distribution noted on follow-up MRI scans. This is the first report of the use of self-expanding stents in the context of branch pulmonary artery stenosis after the LeCompte manoeuvre. Theoretically and based on our early experience, this technique provides potential safety advantages over the use of more traditional balloon expandable stents.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
08:34Left Atrial Stenosis Induced Pulmonary Venous Arterialization and Group 2 Pulmonary Hypertension in Rat
Published on: November 18, 2018
Related Concept Videos
The Power Flow Problem and Solution
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
Treatment for Pulmonary Arterial Hypertension: Phosphodiesterase Inhibitors
Among the PDE5 inhibitors, sildenafil (Revatio) stands out as a competitive and selective inhibitor. It operates by elevating cellular levels of cGMP and augmenting signaling through the cGMP-PKG pathway, promoting vasodilation. Upon oral...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...