Epidural Intracranial Pressure Measurement in Rats Using a Fiber-optic Pressure Transducer
Published on: April 25, 2012
Measurement of Intracranial Pressure in Freely Moving Rats
Michael R Williamson1, Roseleen F John1, Frederick Colbourne2
1Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada.
Abstract:
Brain injury, such as from stroke and trauma, can be complicated by elevated intracranial pressure (ICP). Although raised ICP can be a significant determinant of morbidity and mortality, clinical studies often report widely varying ICP measurements depending on location of measurement and technique used. For the same reasons, reported ICP measurements also vary widely in animal models. The need for anesthesia or tethered connections with some methods of ICP measurement in animals may introduce additional confounds. Moreover, these methods are not well suited for prolonged, continuous measurement. Here, we describe an approach to continually measure ICP in awake, freely moving rats for several days. This technique uses a commercially available, wireless pressure sensor mounted on the head to measure ICP from the epidural space via a fluid-filled catheter. We have demonstrated that this approach reliably detects elevations in ICP that last for several days after ischemic and hemorrhagic strokes in rat.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Vapor Pressure