Related Experiment Video
Updated: Feb 14, 2026

A Micro-CT-based Method for Characterizing Lesions and Locating Electrodes in Small Animal Brains
Published on: November 8, 2018
Renal Lesion Characterization with Spectral CT: Determining the Optimal Energy for Virtual Monoenergetic
Christoph Schabel1, Bhavik Patel1, Scott Harring1
1From the Departments of Radiology (C.S., B.P., S.H., P.D., R.C.N., D.M.) and Biostatistics and Bioinformatics (A.E.F.), Duke University Medical Center, Box 3808 Erwin Rd, Durham, NC 27710; Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen, Germany (C.S., K.N.); and Department of Computed Tomography, Siemens Medical Solutions USA, Malvern, Pa (J.C.R.).
Abstract:
Purpose To investigate the relationship between energy level of virtual monoenergetic (VM) imaging and sensitivity in the detection of minimally enhancing renal lesions. Materials and Methods Phantoms simulating unenhanced and contrast material-enhanced renal parenchyma were equipped with inserts containing different concentrations of iodine (range, 0-1.15 mg iodine per milliliter). A total of 180 patients (117 men; mean age, 65.2 years ± 13.0 [standard deviation]) with 194 (62 solid, 132 cystic) renal lesions larger than 10 mm in diameter underwent unenhanced single-energy CT and contrast-enhanced dual-energy CT. VM imaging data sets were created for 70, 80, 90, and 100 keV. Renal lesions were measured, and enhancement was calculated. Area under the receiver operating characteristic curve (AUC) for renal lesion characterization was determined by using the DeLong method. Results The AUC was highest at 70 keV and decreased as energy increased toward 100 keV. AUC in the phantom decreased from 98% (95% confidence interval [CI]: 95, 100) at 70 keV to 88% (95% CI: 79, 96) at 100 keV (P = .004). AUC in patients decreased from 96% (95% CI: 94, 98) at 70 keV to 79% (95% CI: 71, 86) at 100 keV (P = .001). In patients with an enhancement threshold of 15 HU, sensitivity in the detection of solid renal lesions decreased between from 91% (49 of 62 [95% CI: 78, 97]) at 70 keV to 48% (33 of 62 [95% CI: 25, 71]) at 100 keV (P < .05), with no change in specificity (93% [120 of 132 {95% CI: 87, 97}] at 70 keV, 97% [125 of 132 {95% CI: 92, 99}] at 100 keV). Conclusion There is a reduction in diagnostic accuracy for renal lesion characterization with increasing VM imaging energy. The 70-keV setting may provide an optimal trade-off between sensitivity and specificity. © RSNA, 2018 Online supplemental material is available for this article.
Related Concept Videos
Optimal Foraging
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
What is Energy?
Free Energy Changes for Nonstandard States
Free Energy