Related Experiment Video
Updated: Feb 14, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Robustness of VMAT and 3DCRT plans toward setup errors in radiation therapy of locally advanced left-sided breast
Christer Andre Jensen1, Ana María Acosta Roa1, Marie Johansen1
1Department of Oncology, Ålesund Hospital, Ålesund, Norway.
Purpose:
The aim of our study was to evaluate and compare the robustness of treatment plans produced using the volumetric modulated arc-therapy (VMAT) and the standard three-dimensional conformal radiotherapy (3DCRT) techniques by estimating perturbed doses induced by localization offsets for deep inspiration breath-hold (DIBH) in locally advanced breast cancer radiation therapy.
Methods:
Twenty patients with left breast carcinoma requiring radiation therapy were analysed in this planning study. Robust VMAT plans regarding minimum CTV doses and standard 3DCRT plans were produced, and perturbed doses were calculated in accordance with localization values from the weekly offline imaging protocol. Offsets from 5 weeks were summed to a perturbed overall treatment plan. Dose criteria for evaluation were coverage and homogeneity of the target, as well as doses to organs at risk.
Results:
VMAT plans resulted in significantly better target coverage compared to 3DCRT, as well as lowered doses to heart and left anterior descending artery, while the perturbed doses were less variable for VMAT than 3DCRT plans. Homogeneity was significantly improved in VMAT plans. The statistical analysis taking all organs into account found that VMAT plans were more robust than 3DCRT to localization offsets (p = .001). The overall mean setup-deviation for the DIBH-patients was less than 2 mm in all directions.
Conclusions:
VMAT plans were more robust on average than conventional 3DCRT plans for DIBH when localization errors were taken into consideration. The combination of robust VMAT planning and DIBH generally improves the homogeneity and target doses.
Related Concept Videos
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
Targeted Cancer Therapies
There are several types of targeted therapies against...
Biological Effects of Radiation
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Random Error

