Evaluation of size, morphology, concentration, and surface effect of gold nanoparticles on X-ray attenuation in

Sara Khademi1, Saeed Sarkar2, Sharmin Kharrazi3

  • 1Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran; Research Center for Molecular and Cellular Imaging (RCMCI), Tehran University of Medical Sciences, Tehran, Iran.

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.9K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
410
Transcription Attenuation in Prokaryotes02:42

Transcription Attenuation in Prokaryotes

Transcriptional attenuation occurs when RNA transcription is prematurely terminated due to the formation of a terminator mRNA hairpin structure.  Bacteria use these hairpins to regulate the transcription process and control the synthesis of several amino acids including histidine, lysine, threonine, and phenylalanine. Transcription attenuation takes place in the non-coding regions of mRNA.
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
18.6K
X-ray Crystallography02:18

X-ray Crystallography

The size of the unit cell and the arrangement of atoms in a crystal may be determined from measurements of the diffraction of X-rays by the crystal, termed X-ray crystallography.
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
26.3K
Factors Affecting Dissolution: Particle Size and Effective Surface Area01:23

Factors Affecting Dissolution: Particle Size and Effective Surface Area

Dissolution kinetics, an essential aspect of oral drug delivery, is significantly influenced by the drug's particle size. According to the Noyes-Whitney dissolution model, the dissolution rate correlates directly with the drug's surface area. The larger the surface area, the higher the drug's solubility in water, leading to a faster drug dissolution rate. Reducing particle size increases the effective surface area, enhancing the dissolution process. Micronization and nanosizing are...
1.7K
Cell Size01:22

Cell Size

Cell sizes vary widely among and within organisms. Bacterial cells range between 1-10 micrometers (μm)and are considerably smaller than most eukaryotic cells. The smallest bacteria are 0.1 μm in diameter—about a thousand times smaller than eukaryotic cells, which typically range from 10-100 μm.
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
132.3K