Related Experiment Video
Updated: Feb 14, 2026

Evaluation of Integrated Anaerobic Digestion and Hydrothermal Carbonization for Bioenergy Production
Published on: June 15, 2014
A Comparison between Different Methods of Estimating Anaerobic Energy Production
Erik P Andersson1, Kerry McGawley1
1Swedish Winter Sports Research Centre, Department of Health Sciences, Mid Sweden University, Östersund, Sweden.
Abstract:
Purpose: The present study aimed to compare four methods of estimating anaerobic energy production during supramaximal exercise. Methods: Twenty-one junior cross-country skiers competing at a national and/or international level were tested on a treadmill during uphill (7°) diagonal-stride (DS) roller-skiing. After a 4-minute warm-up, a 4 × 4-min continuous submaximal protocol was performed followed by a 600-m time trial (TT). For the maximal accumulated O2 deficit (MAOD) method the [Formula: see text]O2-speed regression relationship was used to estimate the [Formula: see text]O2 demand during the TT, either including (4+Y, method 1) or excluding (4-Y, method 2) a fixed Y-intercept for baseline [Formula: see text]O2. The gross efficiency (GE) method (method 3) involved calculating metabolic rate during the TT by dividing power output by submaximal GE, which was then converted to a [Formula: see text]O2 demand. An alternative method based on submaximal energy cost (EC, method 4) was also used to estimate [Formula: see text]O2 demand during the TT. Results: The GE/EC remained constant across the submaximal stages and the supramaximal TT was performed in 185 ± 24 s. The GE and EC methods produced identical [Formula: see text]O2 demands and O2 deficits. The [Formula: see text]O2 demand was ~3% lower for the 4+Y method compared with the 4-Y and GE/EC methods, with corresponding O2 deficits of 56 ± 10, 62 ± 10, and 63 ± 10 mL·kg-1, respectively (P < 0.05 for 4+Y vs. 4-Y and GE/EC). The mean differences between the estimated O2 deficits were -6 ± 5 mL·kg-1 (4+Y vs. 4-Y, P < 0.05), -7 ± 1 mL·kg-1 (4+Y vs. GE/EC, P < 0.05) and -1 ± 5 mL·kg-1 (4-Y vs. GE/EC), with respective typical errors of 5.3, 1.9, and 6.0%. The mean difference between the O2 deficit estimated with GE/EC based on the average of four submaximal stages compared with the last stage was 1 ± 2 mL·kg-1, with a typical error of 3.2%. Conclusions: These findings demonstrate a disagreement in the O2 deficits estimated using current methods. In addition, the findings suggest that a valid estimate of the O2 deficit may be possible using data from only one submaximal stage in combination with the GE/EC method.
Related Concept Videos
ATP and Energy Production
Cell Potential and Free Energy
Thermodynamics is the branch of physics dealing with the relationship between heat and other forms of energy. In an electrochemical cell, chemical energy is converted into electrical energy.
Thus, a link can be predicted between cell potential, free energy change, and the equilibrium constant for the reaction. Cell potential can also be measured as the oxidant or the reducing strength, and similar acid-base strength measures are reflected in equilibrium...
Free Energy
Bond Energies and Bond Lengths
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Free Energy Changes for Nonstandard States

