Related Experiment Video
Updated: Feb 14, 2026

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic
Alexander Cm Chong1,2, Daniel J Prohaska2,3, Brian P Bye2
1Via Christi Health, Department of Graduate Medical Education, Wichita, KS.
Introduction:
With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different stacked half-hitch configuration and different braided suture materials on arthroscopic knot integrity.
Methods:
Three different suture materials tied with five different RHAPs in arthroscopic knots were compared. A single load-to-failure test was performed and the mean ultimate clinical failure load was obtained.
Results:
Significant knot holding strength improvement was found when one half-hitch was reversed as compared to baseline knot. When two of the half-hitches were reversed, there was a greater improvement with all knots having a mean ultimate clinical failure load greater than 150 newtons (N). Comparison of the suture materials demonstrated a higher mean ultimate clinical failure load when Force Fiber® was used and at least one half-hitch was reversed. Knots tied with either Force Fiber® or Orthocord® showed 0% chance of knot slippage while knots tied with FiberWire® or braided fishing line had about 10 and 30% knot slippage chances, respectively.
Conclusions:
A significant effect was observed in regards to both stacked half-hitch configuration and suture materials used on knot loop and knot security. Caution should be used with tying three RHAPs in arthroscopic surgery, particularly with a standard knot pusher and arthroscopic cannulas. The findings of this study indicated the importance of three RHAPs in performing arthroscopic knot tying and provided evidence regarding discrepancies of maximum clinical failure loads observed between orthopaedic surgeons, thereby leading to better surgical outcomes in the future.
More Related Videos
06:14The Combination of Transcranial Alternating Current Stimulation and Electroencephalogram
Published on: October 10, 2025
11:11Effects of Transcranial Alternating Current Stimulation on the Primary Motor Cortex by Online Combined Approach with Transcranial Magnetic Stimulation
Published on: September 23, 2017
Related Concept Videos
Combined Effects of Drugs: Synergism
Such synergistic combinations...
Combined Effects of Drugs: Antagonism
The most common type is receptor antagonism, where one drug acts as an antagonist to block the effects of another drug by...
Alternative RNA Splicing
There are five types of alternative RNA splicing that vary in the ways the pre-mRNA segments are removed or retained in the mature mRNA. The first...
Alternative RNA Splicing
Reliability and Validity
Null and Alternative Hypotheses
The null hypothesis, denoted by H0 is a statement of no difference between the variables—they are not related. This can often be considered the status quo. As a result if you cannot accept the null, it requires some action.
The alternative hypothesis, denoted by H1 or Ha, is a claim about the...