Related Experiment Video
Updated: Feb 14, 2026

Cutting Procedures, Tensile Testing, and Ageing of Flexible Unidirectional Composite Laminates
Published on: April 27, 2019
Flexible and precise dosing of enalapril maleate for all paediatric age groups utilizing orodispersible minitablets
Yasmin Thabet1, Jennifer Walsh2, Joerg Breitkreutz1
1Heinrich Heine University Duesseldorf, Universitaetsstrasse 1, 40225 Duesseldorf, Germany.
Abstract:
Enalapril is an off-patent angiotensin-converting enzyme inhibitor for which no paediatric age-appropriate formulation is commercially available in Europe, and enalapril maleate (EM) orodispersible minitablets (ODMTs) have previously been formulated within the LENA (labelling enalapril from neonates to adolescents) project. In this study, a dilution method has been developed by dispersing the lowest dose strength ODMTs to enable flexible and precise EM dosing during the dose titration phase of the therapy. Furthermore, the physicochemical stability of the ODMTs has been investigated in child-friendly beverages and the administration of ODMTs via nasogastric tubes (NGT) of different sizes and materials has been evaluated. The results for the ODMT dilution procedure reveal that dispersion within an oral syringe is preferred over dispersion in a separate container, leading to flexible and precise dosing down to 0.025 mg EM. Although ODMTs were stable in the beverages over the investigated time period, dispersion in tap water only is recommended due to prolonged disintegration times within the other beverages. Dispersed ODMTs can be administered through NGTs of CH5. Almost no adsoprtion of EM on silicone, polyurethane or polyvinyl chloride could be observed. The ODMT concept together with the investigated dispersion method enables the safe administration of EM for all paediatric subpopulations from new-borns to adolescents.
More Related Videos
06:31Precision Implementation of Minimal Erythema Dose MED Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
08:59Utilizing the Precision-Cut Lung Slice to Study the Contractile Regulation of Airway and Intrapulmonary Arterial Smooth Muscle
Published on: May 5, 2022
Related Concept Videos
Aging
Cellular Clock Theory
The cellular clock theory posits that the human lifespan is closely tied to the finite capacity of cells to divide, a phenomenon governed by telomeres, which are protective caps at the ends of...
Uncertainty in Measurement: Accuracy and Precision
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Accuracy and Precision