How reliable are ADC measurements? A phantom and clinical study of cervical lymph nodes
Bastien Moreau1, Antoine Iannessi1, Christopher Hoog1
1Department of Radiology, Centre Antoine Lacassagne, 06100, Nice, France.
Objective:
To assess the reliability of ADC measurements in vitro and in cervical lymph nodes of healthy volunteers.
Methods:
We used a GE 1.5 T MRI scanner and a first ice-water phantom according to recommendations released by the Quantitative Imaging Biomarker Alliance (QIBA) for assessing ADC against reference values. We analysed the target size effect by using a second phantom made of six inserted spheres with diameters ranging from 10 to 37 mm. Thirteen healthy volunteers were also scanned to assess the inter- and intra-observer reproducibility of volumetric ADC measurements of cervical lymph nodes.
Results:
On the ice-water phantom, the error in ADC measurements was less than 4.3 %. The spatial bias due to the non-linearity of gradient fields was found to be 24 % at 8 cm from the isocentre. ADC measure reliability decreased when addressing small targets due to partial volume effects (up to 12.8 %). The mean ADC value of cervical lymph nodes was 0.87.10-3 ± 0.12.10-3 mm2/s with a good intra-observer reliability. Inter-observer reproducibility featured a bias of -5.5 % due to segmentation issues.
Conclusion:
ADC is a potentially important imaging biomarker in oncology; however, variability issues preclude its broader adoption. Reliable use of ADC requires technical advances and systematic quality control.
Key Points:
• ADC is a promising quantitative imaging biomarker. • ADC has a fair inter-reader variability and good intra-reader variability. • Partial volume effect, post-processing software and non-linearity of scanners are limiting factors. • No threshold values for detecting cervical lymph node malignancy can be drawn.
More Related Videos
09:10Generation of Lymph Node-fat Pad Chimeras for the Study of Lymph Node Stromal Cell Origin
Published on: December 16, 2013
12:53Collection and Processing of Lymph Nodes from Large Animals for RNA Analysis: Preparing for Lymph Node Transcriptomic Studies of Large Animal Species
Published on: May 19, 2018
Related Concept Videos
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Reliability and Validity
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Distribution Reliability and Automation
Hypertension III: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies