Related Experiment Video
Updated: Feb 14, 2026

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
Published on: June 21, 2011
Tilted-wire method for measuring resolution properties of CT images under extremely low-contrast and high-noise
Chiaki Tominaga1, Hiroki Azumi2, Mitsunori Goto1,3
1Health Sciences, Graduate School of Medicine, Tohoku University, Seiryo-machi 2-1, Aoba-ku, Sendai, 980-8575, Japan.
Abstract:
Edge methods are predominantly used for modulation transfer function (MTF) measurements in computed tomography (CT) images reconstructed using iterative methods. However, edge methods employ a relatively large and distinct test object, which is intended to simulate relatively large and distinct clinical organs. If one wants to assess the image quality of a small low-contrast object that is visually indistinct against a noisy background, a small and indistinct test object is desired. Another concern is that information related to the signal amount is discarded during MTF measurements. Choosing a weak impulse as the ultimately small test object, we have developed a tilted-wire method, which is a type of point spread function (PSF) method compatible with extremely low contrast-to-noise ratio (CNR) conditions. The signal amount is measured as the PSF volume. We used two commercial CT systems to evaluate the measurement accuracy of the tilted-wire method. When ensemble-averaged images are used, one can measure the MTF even when the wire is indiscernible from noise. The measurement error under such conditions is a few percent for both the MTF and signal amount. We also applied the tilted-wire method to two hybrid iterative reconstruction methods, namely AIDR-3D and ASiR. The results show that the MTF of ASiR is completely CNR-dependent, but that of AIDR-3D is noise-dependent. The signal amount obtained with ASiR is unchanged from that obtained through filtered back-projection (FBP). The signal amount obtained with AIDR-3D is less than that obtained through FBP, depending on the noise level.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Physical and Chemical Properties of Matter
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Absolute and Local Extreme Values

