Related Experiment Video
Updated: Feb 14, 2026

A Mouse Model of Orotracheal Intubation and Ventilated Lung Ischemia Reperfusion Surgery
Published on: September 9, 2022
[Behaviour of stroke volume variation in hemodynamic stable patients during thoracic surgery with one-lung
María Lema Tome1, Francisco Andrés De la Gala1, Patricia Piñeiro1
1Hospital General Universitario Gregorio Marañón, Departamento de Anestesiología y Reanimación, Madri, Espanha.
Introduction:
In last few years, emphasis was placed in goal-directed therapy in order to optimize patient's hemodynamic status and improve their prognosis. Parameters based on the interaction between heart and lungs have been questioned in situations like low tidal volume and open chest surgery. The goal of the study was to analyze the changes that one-lung ventilation can produce over stroke volume variation and to assess the possible impact of airway pressures and lung compliance over stroke volume variation.
Methods:
Prospective observational study, 112 patients undergoing lung resection surgery with one-lung ventilation periods were included. Intravenous fluid therapy with crystalloids was set at 2mL.kg-1.h-1. Hypotension episodes were treated with vasoconstrictive drugs. Two-lung ventilation was implemented with a TV of 8mL.kg-1 and one-lung ventilation was managed with a TV of 6mL.kg-1. Invasive blood pressure was monitored. We recorded the following cardiorespiratory values: heart rate, mean arterial pressure, cardiac index, stroke volume index, airway peak pressure, airway plateau pressure and static lung compliance at 3 different times during surgery: immediately after lung collapse, 30minutes after initiating one-lung ventilation and after restoration of two-lung ventilation.
Results:
Stroke volume variation values were influenced by lung collapse (before lung collapse14.6 (DS) vs. OLV 9.9% (DS), p < 0.0001); or after restoring two-lung ventilation (11.01 (DS), p < 0.0001). During two-lung ventilation there was a significant correlation between airwaypressures and stroke volume variation, however this correlation lacks during one-lung ventilation.
Conclusion:
The decrease of stroke volume variation values during one-lung ventilation with protective ventilatory strategies advices not to use the same threshold values to determine fluid responsiveness.
More Related Videos
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
The Periodic Table
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...

