Related Experiment Video
Updated: Feb 14, 2026

Contrast-Matching Detergent in Small-Angle Neutron Scattering Experiments for Membrane Protein Structural Analysis and Ab Initio Modeling
Published on: October 21, 2018
Determination of cesium transfer factors by instrumental neutron activation analysis
G Bátor1, A Bednár1, T J Glover2
1Institute of Radiochemistry and Radioecology, University of Pannonia, PO Box 158, 8201, Veszprém, Hungary.
Abstract:
Food-chain models are used to predict radionuclide ingestion after fallout deposition. These models include those transfer processes (soil-to-plant transfer factor(s) [TF], plant-to-animal transfer coefficient(s) [TC] and concentration ratio [CR]) that are likely to be important for radiological assessment. The range of variability for transfer factors for the same plant groups is great, about 4-5 orders of magnitude, which limits their applicability. A better way to determine the best estimate the factors for radiocaesium and other important radionuclides is if the site-specific data are available. Soil, plant and animal samples were collected from a pasture area in Hungary during the vegetation period in 2016. Stable 133Cs concentration was analysed by comparative method with neutron activation analysis (NAA). The comparator and the samples were irradiated in thermal neutron flux 2.55 × 1012 ncm-2s-1 for 2 h (soil) and 6 h (vegetation, animal samples) in the TRIGA Mark II research reactor at the Nuclear Engineering Teaching Laboratory. After an appropriate decay time (12 days) the samples were measured by gamma-spectrometry and analysed. The observed stable caesium TCpm (0.48-0.53) and CRpm (0.41-0.45) were very close to 137Cs factors in the IAEA 2009 Report of 0.49 and 0.54, respectively. This methodology is particularly suitable for the simultaneous study of natural caesium in ecosystem compartments. Consequently, the transfer of stable caesium in a pasture field may be regarded as a useful analogy in predicting the long-term changes of 137Cs affected by site-specific environmental factors.
Related Concept Videos
Factors Affecting Activity Coefficient
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
Transcription Factors
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers
Uncertainty in Measurement: Reading Instruments