Odijk excluded volume interactions during the unfolding of DNA confined in a nanochannel

Jeffrey G Reifenberger1, Han Cao1, Kevin D Dorfman2

  • 1BioNano Genomics Inc., 9640 Towne Centre Drive, Suite 100, San Diego, CA 92121.

Macromolecules
|February 27, 2018
PubMed

Related Concept Videos

The Unfolded Protein Response01:37

The Unfolded Protein Response

The ER is the hub of protein synthesis in a cell. It has robust systems to quality control protein folding and also for degradation of terminally misfolded proteins. Under normal conditions, a small proportion of misfolded proteins that cannot be salvaged need to be transported to the cytoplasm by the ER-associated degradation or ERAD pathways. However, if the ERAD cannot handle the misfolded proteins, the cell activates the unfolded protein response or UPR to adjust the protein folding...
6.5K
Regulation of the Unfolded Protein Response01:31

Regulation of the Unfolded Protein Response

Inositol-requiring kinase one or IRE1 is the most conserved eukaryotic unfolded protein response (UPR) receptor. It is a type I transmembrane protein kinase receptor with a distinctive site-specific RNase activity. As the binding mechanics of the misfolded proteins with the N-terminal domain of IRE-1 are unclear, three binding models — direct, indirect, and allosteric -- are proposed for receptor activation. Nevertheless, it is known that once a misfolded protein associates with IRE1, it...
3.1K
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.9K
Volume of Distribution01:20

Volume of Distribution

The apparent volume of distribution (Vd) is a crucial pharmacokinetic parameter representing the hypothetical body fluid volume into which a drug disperses. It is calculated based on the total amount of drug in the body (estimated from the administered dose and bioavailability) divided by the plasma drug concentration. The total amount of drug in the body does not directly refer to the dose given but is derived by accounting for absorption, distribution, metabolism, and excretion processes.
1.4K
Problem Solving: Volume01:13

Problem Solving: Volume

The volume of a fuel tank mounted on the wing of a jet aircraft can be modeled using the concept of solids of revolution. In this case, the tank is formed by rotating a two-dimensional region, defined by a mathematical function, about the x-axis. The region extends along the axis from zero to two meters, and the resulting three-dimensional shape is symmetric about the axis of rotation. Because the boundary curve lies directly against the axis, the disk method is an appropriate technique for...
88
Respiratory Volumes01:15

Respiratory Volumes

Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
3.1K