Minimally Invasive Plate Osteosynthesis for Distal Tibia Fractures.

Ted C Lai1, Justin J Fleming2

  • 1Foot and Ankle Surgery, Shore Orthopaedic University Associates, 24 MacArthur Boulevard, Somers Point, NJ 08244, USA.

Summary

Minimally invasive plate osteosynthesis (MIPO) offers a solution for distal tibia fractures, reducing complications associated with traditional methods like intramedullary nailing and open reduction internal fixation. This approach promotes better healing and functional outcomes.

Related Concept Videos

Bones of the Lower Limb: Tibia and Fibula01:10

Bones of the Lower Limb: Tibia and Fibula

The tibia is the main weight-bearing bone of the lower leg. It is larger than the fibula with which it is paired. The tibia is also the second longest bone in the body and is located right below the skin. The proximal end of the tibia forms the medial and the lateral condyle, which articulates with the condyles of the femur to form the knee joint. Between the articulating surfaces is the irregular elevated area known as the intercondylar eminence that serves as the inferior attachment point for...
9.8K
Fractures: Bone Repair01:27

Fractures: Bone Repair

Treatment for a fracture is based on the type of break, the bone affected, and the patient's age.
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
5.6K
Types of Errors: Detection and Minimization01:12

Types of Errors: Detection and Minimization

Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
11.5K
Column Efficiency: Plate Theory01:10

Column Efficiency: Plate Theory

Band broadening in a chromatography column is measured by its efficiency. This is determined by the number of theoretical plates (N). Theoretical plate theory states that a separation column consists of a continuous series of imaginary plates where solute equilibration occurs between stationary and mobile phases.
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
2.1K
Electric Field of Parallel Conducting Plates01:16

Electric Field of Parallel Conducting Plates

Gauss' law relates the electric flux through a closed surface to the net charge enclosed by that surface. Gauss's law can be applied to find the electric field and the charge enclosed in a region depending on its charge distribution.
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
1.8K
Fluid Pressure over Curved Plate of Constant Width01:12

Fluid Pressure over Curved Plate of Constant Width

When a curved plate of constant width is submerged in a liquid, the pressure acting normal to the plate varies continuously both in magnitude and direction. Calculating the magnitude and location of the resultant force at a point is often challenging for such cases. One of the methods to determine the resultant force and its location involves separately calculating the horizontal and vertical components of the resultant force. This complex calculation can be simplified by representing the...
2.0K