Complications of Radial Column Plating of the Distal Radius
Samuel E Galle1, Neil G Harness2, Jacques H Hacquebord3
1Columbia University, New York, NY, USA.
Abstract:
Background: Distal radius fractures treated with open reduction and internal fixation are commonly stabilized with a volar locking plate; however, more complex fracture patterns may require supplemental fixation with fragment-specific implants. The objective of this study was to evaluate the outcomes of distal radius fractures treated with radial column plates. Methods: A consecutive series of 61 patients who sustained distal radius fractures underwent radial column plating alone or in conjunction with other implants between August 2006 and January 2014. Thirty-one patients returned for follow-up or returned a mailed questionnaire at an average of 4.1 years. The outcomes measures included Visual Analog Scale (VAS); Disabilities of the Arm, Shoulder and Hand (DASH); and Patient-Rated Wrist Evaluation (PRWE) scores. Results: Sixty-one patients with a mean age of 55 years (range, 20-87) met inclusion criteria and were available for follow-up or chart review at an average of 5.2 years (range, 1.6-9.0 years). Seventeen of 61 (28%) underwent radial column plate removal. Twenty patients returned for final follow-up examination, and 11 completed questionnaires via mail. Subjective scores included a mean postoperative VAS of 0.72, DASH score of 17.2, and PRWE score of 15.7. Hardware sensitivity and wrist stiffness were the most common complications at final follow-up. Conclusions: Radial column plating of the distal radius is a safe treatment modality and a valuable adjunct in the setting of complex distal radius fractures, but patients should be counseled that there is a 28% chance that hardware removal may be required. Our retrospective review found evidence of few complications and objective scores consistent with return to normal function.
More Related Videos
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Radius of Gyration of an Area
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...
Degree of Curvature and Radius of Curvature
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...