Related Experiment Video
Updated: Feb 13, 2026

Intracavernosal Pressure Recording to Evaluate Erectile Function in Rodents
Published on: June 6, 2018
Comparison of two cannulation methods for assessment of intracavernosal pressure in a rat model
Shankun Zhao1, Ran Kang2, Tuo Deng1
1Department of Urology & Andrology, Minimally Invasive Surgery Center, Guangdong Provincial Key Laboratory of Urology, The First Affiliated Hospital of Guangzhou Medical University. Guangzhou, Guangdong, China.
Abstract:
Intracavernous pressure (ICP) measurement is a well-established technique for assessing the erectile function, which was performed by cannulating either crus or shaft of the penis. However, there are no studies concerning the experimental performance of the two cannulation sites yet. The aim of this study was to compare the measuring outcomes using two different cannulation sites. To validate the capacity of our study, both normal and the castration-induced erectile dysfunction rat models were conducted. Fifty adult male Sprague-Dawley rats were randomized equally into two groups: an intact group and a castration group. Five rats from each group firstly underwent different stimulation parameters to detect the optimal erectile responses. The residual rats in each group were further assigned into two subgroups (n = 10 per subgroup) according to two different cannulation sites (crus or shaft of the corpus cavernosum). The ICP values were compared between groups after different interventions. The optimal parameters for mean maximum ICP were recorded at 2.5V and a frequency of 15 Hz. The rats under the two different cannulation sites tended to show similar ICP values in both the intact and the castration groups. However, the success rate in monitoring ICP was significantly higher in the groups cannulating into the shaft of the penis compared to the crus (100% vs. 70%; P = 0.02). Our data suggested that the method of cannulation into the penile shaft could serve as a better alternative for the ICP measurement in rats.
More Related Videos
13:17The Mesenteric Lymph Duct Cannulated Rat Model: Application to the Assessment of Intestinal Lymphatic Drug Transport
Published on: March 6, 2015
08:59Method of Isolated Ex Vivo Lung Perfusion in a Rat Model: Lessons Learned from Developing a Rat EVLP Program
Published on: February 25, 2015
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Assessing Blood pressure in the Leg
Preparation:
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...