Related Experiment Video
Updated: Feb 13, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Midterm Survivorship and Patient Satisfaction of Robotic-Arm-Assisted Medial Unicompartmental Knee Arthroplasty: A
Laura J Kleeblad1, Todd A Borus2, Thomas M Coon3
1Department of Orthopaedic Surgery and Computer Assisted Surgery, Hospital for Special Surgery, Weill Medical College of Cornell University, New York, NY.
Background:
Studies have showed improved accuracy of lower leg alignment, precise component position, and soft-tissue balance with robotic-assisted unicompartmental knee arthroplasty (UKA). No studies, however, have assessed the effect on midterm survivorship. Therefore, the purpose of this prospective, multicenter study was to determine midtem survivorship, modes of failure, and satisfaction of robotic-assisted medial UKA.
Methods:
A total of 473 consecutive patients (528 knees) underwent robotic-arm-assisted medial UKA surgery at 4 separate institutions between March 2009 and December 2011. All patients received a fixed-bearing, metal-backed onlay tibial component. Each patient was contacted at minimum 5-year follow-up and asked a series of questions to determine survival and satisfaction. Kaplan-Meier method was used to determine survivorship.
Results:
Data were collected for 384 patients (432 knees) with a mean follow-up of 5.7 years (5.0-7.7). The follow-up rate was 81.2%. In total, 13 revisions were performed, of which 11 knees were converted to total knee arthroplasty and in 2 cases 1 UKA component was revised, resulting in 97% survivorship. The mean time to revision was 2.27 years. The most common failure mode was aseptic loosening (7/13). Fourteen reoperations were reported. Of all unrevised patients, 91% was either very satisfied or satisfied with their knee function.
Conclusion:
Robotic-arm-assisted medial UKA showed high survivorship and satisfaction at midterm follow-up in this prospective, multicenter study. However, in spite of the robotic technique, early fixation failure remains the primary cause for revision with cemented implants. Comparative studies are necessary to confirm these findings and compare to conventional implanted UKA and total knee arthroplasty.
Related Concept Videos
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bioavailability Study Design: Healthy Subjects Versus Patients
Patient-centered Care
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients