Related Experiment Video
Updated: Feb 13, 2026
![Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F67458.jpg&w=3840&q=50)
Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
Paclitaxel-induced dermal hypersensitivity lesions: 2-deoxy-2-[18F]fluoro-D-glucose positron emission
Inci Uslu Biner1, Ebru Tatci1, Berna Akinci Ozyurek2
1Department of Nuclear Medicine, Ataturk Chest Diseases and Thoracic Surgery Training and Research Hospital, Ankara, Turkey.
Abstract:
Paclitaxel is frequently used for the treatment of patients with nonsmall cell lung cancer. Hypersensitivity reactions (HSRs) have been one of the toxicities observed with administration of paclitaxel. Here, we presented a case of a 49-year-old man with a history of right lung mass proven by biopsy to be a nonsmall cell lung cancer (squamous cell carcinoma) who developed HSR during therapy. In addition to the hypermetabolic primary malignancy, a positron emission tomography/computed tomography (PET/CT) scan showed multiple hypermetabolic skin lesions at several parts of the body. These cutaneous lesions were resolved in the restaging PET/CT scan performed after completion of the six cycles of chemotherapy. This is the first documented case of comparative PET/CT findings of a paclitaxel-induced hypersensitivity.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H
2° Amines to N-Nitrosamines: Reaction with NaNO2