Managing high risk glaucoma with the Ahmed valve implant: 20 years of experience
Tryfon Rotsos1, Anastasia Tsioga1, Konstantinos Andreanos1
1Department of Ophthalmology, University of Athens, General Hospital of Athens, Mesogion 154 Ave, Athens 11527, Greece.
Aim:
To estimate the efficacy and safety of the Ahmed implant in patients with high risk for failure after glaucoma surgery.
Methods:
In 342 eyes of 342 patients with refractory glaucoma, even with application of medical treatment, the Ahmed valve was introduced for intraocular pressure (IOP) control, in the period of the last 20y. The nature of glaucoma was neovascular in 162 eyes, pseudophakic or aphakic in 49 eyes, inflammatory in 29 eyes and non working previous antiglaucomatic surgical interventions in 102 eyes.
Results:
Follow-up ranged from 18 to 120mo with a mean follow-up of 63.2mo. IOP before the operation decreased from 31.6±10.4 mm Hg to 18.3±5.4 mm Hg (no systemic treatment) at the end of follow up period. When we compared the IOP values before the operation using ANOVA showed statistically significant difference (P<0.001). The success rate was 85.2% during the first semester, 76.8% at 12mo and 50.3% at the end of follow up period (18 to 120mo after implantation). Success rate was 25.7% in neovascular glaucoma, 63.2% in aphakic glaucoma and 73.8% in non working previous antiglaucomatic surgical interventions. Complications due to the implant were: serous choroidal detachment in 14.8%, blockage of the tube in 2.8%, malposition of the tube in 4.9%, suprachoroidal hemorrhage in 2.1%, cataract progression in 39.6% (phakic eyes), shallow anterior chamber in 9.2%, hyphaema in 28.9%, exposure of valve in 2.6%, exposure of tube in 9.3%, hypotony in 4.9% and conjunctival fibrosis in 41.5%.
Conclusion:
Despite the fact that Ahmed valve implant had suchlike results as other implants concerning the IOP control, complications rate due to hypotony or over filtration in the first days after the intervention are not that frequent as with other valve implants.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Relative Risk