Related Experiment Video
Updated: Feb 13, 2026

Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.
Published on: January 27, 2015
Positive end-expiratory pressure-induced increase in external jugular venous pressure does not predict fluid
Min Hur1, Seokha Yoo1, Jung-Yoon Choi1
1Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
Background:
Dynamic change in central venous pressure (CVP) was associated with fluid responsiveness. External jugular venous pressure (EJVP) may reliably estimate CVP and have the advantages of being less invasive. We investigated whether increase in EJVP induced by positive end-expiratory pressure (PEEP) could be a reliable predictor of fluid responsiveness in patients undergoing robot-assisted laparoscopic prostatectomy (RALP).
Methods:
Fifty patients who underwent RALP with steep Trendelenburg position were enrolled. PEEP of 10 cmH2O was applied for 5 min and then 300 ml of colloid was administered. EJVP, stroke volume variation (SVV), and cardiac index calculated by pulse contour method were measured before and after the PEEP challenge and colloid administration. Increase in cardiac index > 10% was used to define the fluid responsiveness.
Results:
Twenty-six patients were fluid responders. Neither the increase in EJVP after the initial PEEP nor SVV was significantly different between responders and non-responders. They were not significantly correlated with an increase in cardiac index. The areas under the receiver operating characteristic curve (AUC) of these two variables were not significantly greater than 0.5. However, a post hoc analysis revealed that AUC of a decrease in EJVP after removal of PEEP was significantly greater than 0.50.
Conclusion:
Our study results suggested that SVV and increase in EJVP after applying PEEP were not accurate predictors of fluid responsiveness during RALP. Further studies are required to find an adequate preload index in robot-assisted urologic surgery with steep Trendelenburg position.
Related Concept Videos
Pressure of Fluids
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Vapor Pressure of Fluid
When a liquid is placed in a closed container with a small air space, and the space is evacuated, vapor molecules will...
Vapor Pressure
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...