Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided
Hiroaki Hasegawa1, Jiro Sato2, Ikuo Kobayashi3
1Department of Radiology, The University of Tokyo Hospital, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan. hasegawah-rad@h.u-tokyo.ac.jp.
Abstract:
The authors aimed to evaluate the effects of the half-scan mode on image quality and physician exposure to radiation in computed tomography (CT)-guided interventional radiology (IVR) to the right lung using an intermittent CT fluoroscopy technique for measuring phantom surface dose distribution and image noise. For the half-scan mode, settings at 0°, 90°, 180°, and 270° were used as the central axis of the X-ray exposure range on the chest phantom. With the center of the ventral side in the chest phantom defined as 0°, optically stimulated luminescent dosimeters were attached at five positions at 30° intervals on the right side of the phantom surface. Securing a space for device operation during the procedure is necessary. The couch was shifted downward by 50 mm to reproduce the conditions used for measurement in clinical settings. Image noise and contrast-to-noise ratio were measured to assess image quality; subjective evaluation was performed using simulated lung nodules placed in the phantom. The phantom surface dose distribution in the measured half-scan mode depended on the angle setting. Additionally, the phantom surface dose in the half-scan mode at the 90° setting was reduced by approximately 50%; however, image quality was clearly decreased. In CT-guided IVR to the right lung, using a lead drape and half-scan mode according to the procedural situation is important.
More Related Videos
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...