Identification of ortho-Substituted Benzoic Acid/Ester Derivatives via the Gas-Phase Neighboring Group Participation

William D Blincoe1, Agustina Rodriguez-Granillo2, Josep Saurí1

  • 1Analytical Research and Development, Merck and Co., Inc., Rahway, NJ, 07065, USA.

Related Concept Videos

Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.4K
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation01:01

Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation

The fragmentation patterns observed for compounds such as carboxylic acids, esters, and amides in the mass spectra include ⍺-cleavage and McLafferty rearrangement. Fragmentation by ⍺-cleavage preferentially occurs at the carbon-carbon bond at the ⍺-position next to the carboxylic group to generate a neutral radical and a cation. Long chain compounds with hydrogen at their γ-carbon undergo McLafferty rearrangement to give a radical cation and a neutral alkene.
For example, the...
2.6K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.6K
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.9K
Peptide Identification Using Tandem Mass Spectrometry01:33

Peptide Identification Using Tandem Mass Spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
8.6K
Nomenclature of Carboxylic Acid Derivatives: Acid Halides, Esters, and Acid Anhydrides01:16

Nomenclature of Carboxylic Acid Derivatives: Acid Halides, Esters, and Acid Anhydrides

Naming Acid Halides
The IUPAC and common names of acid halides are derived from the corresponding carboxylic acids, by changing “ic acid” to “yl halide.” For example, as shown below, the IUPAC name ethanoyl chloride is derived from ethanoic acid, and the common name, acetyl chloride, is obtained from acetic acid.
6.0K