Patient radiation dose and fluoroscopy time during ERCP: a single-center, retrospective study of influencing factors

Ekaterina Saukko1, Juha M Grönroos2,3, Paulina Salminen2,3

  • 1a The Medical Imaging Centre of Southwest Finland, Turku University Hospital , Turku , Finland.

Abstract

Related Concept Videos

Patient-centered Care01:13

Patient-centered Care

Patient-centered care involves delivering care beyond inpatient hospitalization. Reflective practice can enhance a patient-centered approach. Reflective practice is a process of reasoning that considers all aspects of the present situation, including practicalities, learning from personal practice, and consideration of patient needs. Patients appreciate care decisions made while considering their input. Involving the patient in their care provides the patient with a sense of contribution rather...
3.1K
Other Factors Affecting Respiration Centers01:17

Other Factors Affecting Respiration Centers

Breathing is primarily an involuntary activity regulated by the brainstem respiratory centers. However, it can also be consciously controlled, allowing us to hold our breath or take deeper breaths when needed. This voluntary control is facilitated by the cerebral motor cortex, which bypasses the medullary centers to stimulate the respiratory muscles directly.
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical...
1.6K
Bioavailability Study Design: Single Versus Multiple Dose Studies01:11

Bioavailability Study Design: Single Versus Multiple Dose Studies

Bioavailability studies are essential for understanding how a drug is absorbed, distributed, metabolized, and excreted in the body. These studies assess the extent and rate at which the active pharmaceutical agent becomes available at the site of action. The design of bioavailability studies can involve single-dose or multiple-dose regimens, each with distinct advantages and limitations.Single-dose studies are the preferred approach due to their simplicity and reduced drug exposure for...
253
Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
18.1K
Bioavailability: Influencing Factors01:22

Bioavailability: Influencing Factors

Bioavailability refers to the extent and rate at which a drug reaches systemic circulation in its active form. Extent refers to the amount of the drug that makes it into circulation, while rate is the speed at which it enters circulation. It is influenced by several factors critical for optimizing drug formulations, dosing regimens, and therapeutic outcomes.Physicochemical properties of drugs and formulationsThe solubility, stability, and dissolution rate of a drug significantly impact its...
405
Chemical Factors Affecting Respiration Centers01:31

Chemical Factors Affecting Respiration Centers

Chemical factors such as changing CO2, O2, and H+ levels in arterial blood play a critical role in influencing respiration depth and rates. These variations are detected by chemoreceptors—specialized sensors located in two primary body areas. Central chemoreceptors are found throughout the brain stem, including the ventrolateral medulla, while peripheral chemoreceptors are located in the aortic arch and carotid arteries.
CO2 has a potent influence on respiration and is strictly regulated....
2.4K