Related Experiment Video
Updated: Feb 13, 2026

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
Published on: August 17, 2015
Variance component analysis to assess protein quantification in biomarker validation: application to selected
Amna Klich1,2,3,4, Catherine Mercier5,6,7,8, Laurent Gerfault9,10
1Service de Biostatistique-Bioinformatique, Hospices Civils de Lyon, 162, avenue Lacassagne, F-69003, Lyon, France. amna.klich@chu-lyon.fr.
Background:
In the field of biomarker validation with mass spectrometry, controlling the technical variability is a critical issue. In selected reaction monitoring (SRM) measurements, this issue provides the opportunity of using variance component analysis to distinguish various sources of variability. However, in case of unbalanced data (unequal number of observations in all factor combinations), the classical methods cannot correctly estimate the various sources of variability, particularly in presence of interaction. The present paper proposes an extension of the variance component analysis to estimate the various components of the variance, including an interaction component in case of unbalanced data.
Results:
We applied an experimental design that uses a serial dilution to generate known relative protein concentrations and estimated these concentrations by two processing algorithms, a classical and a more recent one. The extended method allowed estimating the variances explained by the dilution and the technical process by each algorithm in an experiment with 9 proteins: L-FABP, 14.3.3 sigma, Calgi, Def.A6, Villin, Calmo, I-FABP, Peroxi-5, and S100A14. Whereas, the recent algorithm gave a higher dilution variance and a lower technical variance than the classical one in two proteins with three peptides (L-FABP and Villin), there were no significant difference between the two algorithms on all proteins.
Conclusions:
The extension of the variance component analysis was able to estimate correctly the variance components of protein concentration measurement in case of unbalanced design.
More Related Videos
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Friedman Two-way Analysis of Variance by Ranks
Mass Spectrometry: Overview
Tandem Mass Spectrometry
Mass Spectrometry of Amines
Mass Spectrometry: Isotope Effect