Intracardiac Abscess and Pacemaker Lead Infection Secondary to Hematogenous Dissemination of Methicillin-Sensitive
Kristopher S Pfirman1, Robel Haile2
1Department of Medical Education, Camden Clark Medical Center, Parkersburg, WV, USA.
Abstract:
BACKGROUND Intracardiac abscesses are an unusual occurrence in developed countries. With the increase in use of implantable cardiac devices, the increase use of and advancements in antibiotics, and the longevity of patients with cardiac devices, one may expect an increase in such infections; however, case reports are rare. We are presenting a case in which hematogenous dissemination of methicillin-sensitive Staphylococcus aureus (MSSA) infection from a lower extremity diabetic ulcer propagated into an infected pacemaker lead and ultimately an intracardiac abscess of the right atrium. CASE REPORT A 77-year-old male with a history of MSSA diabetic foot infection complicated by osteomyelitis presented with fever, syncope, and wide complex tachycardia, and he was found to have an intracardiac abscess and fibrinous lead vegetations. The patient was deemed too ill for invasive surgical intervention given his comorbidities, pacemaker generator replacement requirement, and intermittent ventricular tachycardia. The patient was subsequently sent home with oral antibiotics and home hospice per patient and family wishes. CONCLUSIONS This case demonstrated how hematogenous dissemination of MSSA infections from a diabetic foot ulcer and osteomyelitis can seed pacemaker hardware resulting in an intracardiac abscess. Unfortunately, our patient was too ill to undergo all procedures required to eradicate the abscess and infected pacemaker hardware. The standard of care would be complete hardware removal. Conservative management would include indefinite or prolonged antibiotic therapy, with the notion that intracardiac abscesses cannot be cured with antibiotics alone. This conservative management approach would be deemed necessary in a select population that cannot undergo surgical intervention.
Insights
Intracardiac abscesses, though rare, can arise from Staphylococcus aureus bloodstream infections seeding pacemaker leads. Conservative management may be necessary for critically ill patients unable to undergo hardware removal.
Area of Science:
- Cardiology
- Infectious Diseases
- Medical Device Infections
Background:
- Intracardiac abscesses are uncommon in developed nations.
- Increasing use of cardiac devices and antibiotic advancements may lead to more such infections.
- Case reports of intracardiac abscesses remain infrequent.
Observation:
- A case of methicillin-sensitive Staphylococcus aureus (MSSA) bloodstream infection from a diabetic foot ulcer.
- Infection spread hematogenously, seeding a pacemaker lead and forming an intracardiac abscess in the right atrium.
- The patient presented with fever, syncope, and ventricular tachycardia.
Findings:
- The patient had an intracardiac abscess and fibrinous lead vegetations.
- Surgical intervention was not feasible due to comorbidities and patient instability.
- Conservative management with oral antibiotics and hospice was chosen.
Implications:
- Hematogenous spread of MSSA from diabetic ulcers can infect pacemaker hardware, causing intracardiac abscesses.
- Complete hardware removal is the standard of care for intracardiac abscesses.
- Prolonged antibiotic therapy may be considered for select, non-surgical candidates, though complete cure with antibiotics alone is unlikely.
Related Concept Videos
Muscles of the Leg that Move the Foot and Toes
Anterior Compartment
The anterior compartment includes muscles that contribute to the dorsiflexion of the foot. This compartment houses the tibialis anterior, extensor hallucis longus, and extensor digitorum longus muscles....
Secondary Active Transport
Secondary Active Transport
Secondary Healthcare System
Primary and Secondary Growth in Roots and Shoots
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...