Related Experiment Video
Updated: Feb 13, 2026

Low-Cost Single-Port LoCoSP Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
Penoscrotal versus minimally invasive infrapubic approach for inflatable penile prosthesis placement: a single-center
Pietro Grande1, Gabriele Antonini1, Cristiano Cristini1
1Department of Obstetrical and Gynaecological Sciences and Urological Sciences, 'Sapienza' University of Rome, Viale del Policlinico 155, 00161, Rome, Italy.
Purpose:
To compare perioperative results, safety and efficacy profile in patients receiving inflatable penile prosthesis (IPP) via penoscrotal (PS) or minimally invasive infrapubic (MII) approach for erectile dysfunction.
Methods:
A matched-pair analysis was performed including 42 patients undergoing IPP implantation via PS (n = 21) or MII (n = 21) between 2011 and 2016. Clinical and surgical data were prospectively collected. Patients' and partners' outcomes were assessed by the International Index of Erectile Function (IIEF), Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) and Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaires.
Results:
Mean (SD) operative time was 128 (40.6) min in group PS and 91 (43.0) min in group MII (p = 0.041). Complications occurred in 3/21 (14%) and 2/21 (10%) patients in groups PS and MII (p = 0.832). Overall, no differences were observed concerning the device utilisation (p = 0.275). However, in group MII 4/21 (19%) patients were able to resume sexual activity prior to 4 postoperative weeks, while in group PS no patient was (p = 0.012). Mean (SD) scores for questionnaires were similar between groups PS and MII: IIEF [20.9 (7.3) vs. 20.7 (4.8); p = 0.132], patient EDITS [76.0 (25.6) vs. 74.7 (20.8); p = 0.256] and partner EDITS [72.5 (29.1) vs. 73.1 (21.4); p = 0.114]. Similarly, QoLSPP showed comparable results among the groups PS and MII: functional domain [3.9 (1.4) vs. 4.0 (1.2); p = 0.390], personal [4.0 (1.2) vs. 4.1 (1.0); p = 0.512], relational [3.7 (1.5) vs. 3.9 (1.2); p = 0.462] and social [4.0 (1.2) vs. 3.9 (1.2); p = 0.766].
Conclusions:
PS and MII demonstrated to be safe and efficient techniques, leading to high level of both patients and partners satisfaction. Additionally, the minimally invasive infrapubic approach showed a shorter operative time and a tendency for a faster return to sexual activity.
Related Concept Videos
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Wilcoxon Signed-Ranks Test for Matched Pairs
DNA Base Pairing
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
VSEPR Theory and the Effect of Lone Pairs
Center of Gravity