Comparison of conventional color fundus photography and multicolor imaging in choroidal or retinal lesions
Ilkay Kilic Muftuoglu1,2, Raouf Gaber1,3, Dirk-Uwe Bartsch1
1Department of Ophthalmology, Jacobs Retina Center at the Shiley Eye Institute, University of California San Diego, La Jolla, CA, USA.
Purpose:
Our purpose was to compare the characteristics of the retinal and choroidal lesions including choroidal nevus, choroidal melanoma and congenital hypertrophy of the retina pigment epithelium using conventional color fundus photography (CFP) and multicolor imaging (MCI).
Methods:
The paired images of patients with retinal or choroidal lesions were assessed for the visibility of lesion's border, halo and drusen using a grading scale (0-2). The area of the lesion was measured on both imaging modalities. The same grading was also done on the individual color channels of MCI for a further evaluation.
Results:
Thirty-three eyes of 33 patients were included. There were no significant differences in the mean border, drusen and halo visibility scores between the two imaging modalities (p = 0.12, p = 0.70, p = 0.35). However, the mean area of the lesion was significantly smaller on MCI than that on CFP (14.9±3.3 versus 18.7±3.4 mm2, p = 0.01).
Conclusion:
The appearance of choroidal and/ or retinal lesions on MCI may be different than that on CFP. Though MCI can provide similar information with CFP for the features of retinal and/ or choroidal lesions including border, halo and drusen; the infrared light reflection on MCI underestimates the extent of the choroidal lesion by 33%.
Related Concept Videos
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Color Vision
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Enolate Mechanism Conventions
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...