Related Experiment Video
Updated: Feb 13, 2026

Robotic Ablation of Atrial Fibrillation
Published on: May 29, 2015
Safety and efficacy of persistent atrial fibrillation ablation using the second-generation cryoballoon
Kivanc Yalin1,2, Amr Abdin1, Evgeny Lyan1
1Department of Cardiology, Angiology and Intensive Care Medicine, University Heart Center Luebeck, Medical Clinic II, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, 23538, Luebeck, Germany.
Background:
The second-generation cryoballoon (CB) is increasingly used for treatment of persistent atrial fibrillation (AF). Data regarding the clinical outcome and mechanism of arrhythmia recurrence following persistent AF ablation using CB is sparse. In this study, we aimed to assess the efficacy of CB and mechanisms of atrial tachyarrhythmia (ATA) recurrence in patients with persistent AF.
Methods And Results:
A total of 133 patients (66 ± 10 years, 60% male) with symptomatic persistent AF, who were scheduled for PVI using the second-generation CB were enrolled. Follow-up included 24 h Holter recording at 3, 6 and 12 months. Any documented episode of ATA lasting more than 30 s was considered as a recurrent arrhythmic event. All targeted veins were isolated (100%). Phrenic nerve palsy with recovery during follow-up occurred in six patients (4.5%), no patient experienced tamponade or a cerebrovascular event. During 12.6 ± 5.4 months of follow-up, 89/133 (67%) patients were free of ATA recurrences. Multivariable analysis revealed recurrence in the blanking period (HR 11.46, 0.95 CI 3.92-33.49, p < 0.001), presence of cardiomyopathy (HR 2.75, 0.95 CI 1.09-6.96, p = 0.032) and PV abnormality (HR 3.56, 0.95 CI 1.21-10.43, p = 0.021) as predictors for late recurrence.
Conclusion:
In patients with persistent AF, second-generation cryoballoon use is associated with an excellent safety profile and favorable outcomes. Arrhythmia recurrence during the blanking period, presence of cardiomyopathy and PV abnormality were independent predictors of long-term AF recurrence.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Survey Safety
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Self-Efficacy
Household Wiring And Electrical Safety