Related Experiment Video
Updated: Feb 13, 2026

Acquisition of High-Quality Digital Video of Drosophila Larval and Adult Behaviors from a Lateral Perspective
Published on: October 4, 2014
Feasibility study of shutter scan acquisition for region of interest (ROI) digital tomosynthesis
Dohyeon Kim1, Byungdu Jo2, Donghoon Lee1
1Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, Wonju, Gangwon, Korea.
Abstract:
Dose reduction techniques have been studied in medical imaging. We propose shutter scan acquisition for region of interest (ROI) imaging to reduce the patient exposure dose received from a digital tomosynthesis system. A prototype chest digital tomosynthesis (CDT) system (LISTEM, Wonju, Korea) and the LUNGMAN phantom (Kyoto Kagaku, Japan) with lung nodules 8, 10, and 12 mm in size were used for this study. A total of 41 projections with shutter scan acquisition consisted of 21 truncated projections and 20 non-truncated projections. For comparison, 41 projections using conventional full view scan acquisition were also acquired. Truncated projections obtained by shutter scan acquisition were corrected by proposed image processing procedure to remove the truncation artifacts. The image quality was evaluated using the contrast to noise ratio (CNR), coefficient of variation (COV), and figure of merit (FOM). We measured the dose area product (DAP) value to verify the dose reduction using shutter scan acquisition. The ROI of the reconstructed image from shutter scan acquisition showed enhanced contrast. The results showed that CNR values of 8 and 12 mm lung nodules increased by 6.38% and 21.21%, respectively, and the CNR value of 10 mm lung nodule decreased by 3.63%. COV values of the lung nodules were lower in a shutter scan image than in a full view scan image. FOM values of 8, 10, and 12 mm lung nodules increased by 3.06, 2.25, and 2.33 times, respectively. This study compared the proposed shutter scan and conventional full view scan acquisition. In conclusion, using a shutter scan acquisition method resulted in enhanced contrast images within the ROI and higher FOM values. The patient exposure dose of the proposed shutter scan acquisition method can be reduced by limiting the field of view (FOV) to focus on the ROI.
Related Concept Videos
Leaky Scanning
IR Frequency Region: Fingerprint Region
Light Acquisition
The Eukaryotic Promoter Region
Region of Convergence
Regional Terms
Primarily, the human body has two major regions, the axial and appendicular regions. The axial region comprises regions from the head to the abdomen and makes up the central body axis. In contrast,...

