Airborne contaminants during controlled residential fires
Kenneth W Fent1, Douglas E Evans2, Kelsey Babik1
1a Division of Surveillance, Hazard Evaluations, and Field Studies, National Institute for Occupational Safety and Health (NIOSH) , Cincinnati , Ohio.
Firefighters face significant exposure to harmful combustion byproducts like PAHs and VOCs during residential fires. Respiratory protection is crucial, especially during overhaul and ventilation, as air concentrations frequently exceed safety limits.
Area of Science:
- Environmental Health & Safety
- Occupational Health
- Fire Science
Background:
- Residential fires produce complex mixtures of combustion byproducts.
- Modern furnishings contribute unique chemical profiles to fire emissions.
- Firefighter exposure to these toxins is a significant occupational hazard.
Purpose of the Study:
- To quantify airborne concentrations of combustion byproducts during controlled residential fires.
- To assess firefighter exposure levels across various job roles and fire attack tactics.
- To compare exposures between interior and transitional fire attack methods.
Main Methods:
- Controlled residential fires with common 21st-century furnishings were conducted.
- Area and personal air samples were collected for polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs), and hydrogen cyanide (HCN).
- Measurements were taken during active fire, overhaul, and on the fireground, with different fire attack tactics employed.
Main Results:
- Median personal air concentrations for attack and search firefighters exceeded occupational exposure limits for several compounds.
- Hydrogen cyanide (HCN) levels for outside ventilation firefighters surpassed exposure limits and Immediately Dangerous to Life and Health (IDLH) levels.
- Airborne concentrations decreased post-suppression, but some overhaul firefighters still exceeded limits for PAHs and benzene.
- No significant exposure differences were found between interior and transitional fire attack tactics.
Conclusions:
- Firefighters experience high exposures to combustion byproducts, necessitating consistent use of self-contained breathing apparatus (SCBA).
- Overhaul and outside ventilation activities pose particular risks.
- Strategic positioning of command posts upwind of fires is recommended to minimize exposure.
More Related Videos
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
10:36An In Vitro Adult Mouse Muscle-nerve Preparation for Studying the Firing Properties of Muscle Afferents
Published on: September 24, 2014
Related Concept Videos
Design Example: Designing a Residential Plumbing System
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Combinatorial Gene Control
The expression of more than 30,000 genes is controlled by approximately 2000-3000 transcription factors. This is possible because a single transcription factor can recognize more than one regulatory sequence. The specificity in gene...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...