Related Experiment Video
Updated: Feb 13, 2026

Reliable Method for Assessing Seed Germination, Dormancy, and Mortality under Field Conditions
Published on: November 6, 2016
Regional Assessment of Temperature-Related Mortality in Finland
Reija Ruuhela1, Otto Hyvärinen2, Kirsti Jylhä3
1Finnish Meteorological Institute, P.O. Box 503, FI-00101 Helsinki, Finland. reija.ruuhela@fmi.fi.
Abstract:
The aim of this study was to assess regional differences in temperature-mortality relationships across 21 hospital districts in Finland. The temperature dependence of the daily number of all-cause, all-aged deaths during 2000-2014 was studied in each hospital district by using daily mean temperatures, spatially averaged across each hospital district, to describe exposure to heat stress and cold stress. The relationships were modelled using distributed lag non-linear models (DLNM). In a simple model version, no delayed impacts of heat and cold on mortality were taken into account, whereas a more complex version included delayed impacts up to 25 days. A meta-analysis with selected climatic and sociodemographic covariates was conducted to study differences in the relationships between hospital districts. A pooled mortality-temperature relationship was produced to describe the average relationship in Finland. The simple DLNM model version without lag gave U-shaped dependencies of mortality on temperature almost without exception. The outputs of the model version with a 25-day lag were also U-shaped in most hospital districts. According to the meta-analysis, the differences in the temperature-mortality relationships between hospital districts were not statistically significant on the absolute temperature scale, meaning that the pooled mortality-temperature relationship can be applied to the whole country. However, on a relative temperature scale, heterogeneity was found, and the meta-regression suggested that morbidity index and population in the hospital districts might explain some of this heterogeneity. The pooled estimate for the relative risk (RR) of mortality at a daily mean temperature of 24 °C was 1.16 (95% CI 1.12-1.20) with reference at 14 °C, which is the minimum mortality temperature (MMT) of the pooled relationship. On the cold side, the RR at a daily mean temperature of -20 °C was 1.14 (95% CI 1.12-1.16). On a relative scale of daily mean temperature, the MMT was found at the 79th percentile.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
IR Frequency Region: Fingerprint Region

